MAGIO MS-450F Refrigerated / heating circulator
with extremely powerful pressure/suction pump and intuitive touch display
As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. The devices offer extra strong pressure and suction pumps, thus fulfilling the highest demands for temperature control of external applications. Whether in basic research, material testing or technical systems – the MAGIO refrigerated circulators offer high-tech solutions for high customer requirements.
With natural refrigerant
The MAGIO MS-450F is available with natural refrigerant. Order No. 9 032 714.N1
Order number including voltage version | see refrigerant variants |
---|---|
Working temperature range | -30 ... +200 °C |
Temperature stability | ±0.01 °C |
Heating capacity | 2 kW |
Pump capacity flow pressure | 16 ... 31 l/min |
Pump capacity pressure | 0.24 ... 0.92 bar |
Usable bath opening (W x L / D) |
13 x 15 / 15 cm |
Filling volume | 3 ... 4 l |
Total dimensions
(W × L × H) |
23 x 40 x 65 cm |
Product Features
- Ideal for demanding external applications
- Simple control of complex applications
- Continuously adjustable, extremely powerful pressure / suction pump
- Flow rate 16 ... 31 l / min, pressure 0.24 ... 0.92 bar, suction 0.03 ... 0.4 bar
- Large, high-resolution TFT touch display with multilingual user interface
- Parts being in contact with the medium made of stainless steel
- Integrated programmer
- Integrated external Pt100 connection
- USB connection
- RS232 interface for online communication
- Ethernet
- analog interfaces (accessory)
- Class III (FL) according to DIN 12876-1
- Connections for solenoid valve
- Modbus TCP/IP
- Integrated pump connection M16×1
Technical data for MAGIO MS-450F
Total dimensions (W × L × H) |
23 x 40 x 65 cm |
---|---|
Filling volume | 3 ... 4 l |
Weight | 29 kg |
Pump connections | M16x1 male |
Working temperature range | -30 ... +200 °C |
---|---|
Temperature stability | ±0.01 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5 ... +40 °C |
Heating capacity | 2 kW | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 16 ... 31 l/min | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity pressure | 0.24 ... 0.92 bar | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Maximum suction | -0.03 ... -0.4 bar | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Viscosity max. | 70 cSt | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power consumption | 14 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
13 x 15 / 15 cm |
Cooling of compressor | 1-stage Air |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 20 |
Pump function | Pressure Suction Pump |
Pump type | Immersion Pump |
User Interface Language | Chinese / Czech / Dutch / English / French / German / Italian / Japanese / Korean / Polish / Portuguese / Russian / Spanish / Turkish |
Interfaces | Ethernet / Modbus TCP/IP / RS232 / RS485 / Stakei / USB |
---|---|
External pt100 sensor connection | integrated |
Integrated programmer | 8x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 10 Point Calibration |
Temperature display | 7" TFT Touchscreen |
Temperature setting | Touchscreen |
Electronic Timer h:min |
00:00 ... 99:59 |
9032714.N1.01 | 100V/50-60Hz (Nema N5-15 Plug) (R290) |
---|---|
9032714.S1.01 | 100V/50-60Hz (Nema N5-15 Plug) (R449A) |
9032714.N1.02 | 115V/60Hz (Nema N5-15 Plug) (R290) |
9032714.S1.02 | 115V/60Hz (Nema N5-15 Plug) (R449A) |
9032714.N1.33 | 200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R290) |
9032714.S1.33 | 200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R449A) |
9032714.N1.33.chn | 200-230V/50-60Hz (CN Plug) (R290) |
9032714.S1.33.chn | 200-230V/50-60Hz (CN Plug) (R449A) |
9032714.N1.04 | 200-230V/50-60Hz (UK Plug Type BS1363A) (R290) |
9032714.S1.04 | 200-230V/50-60Hz (UK Plug Type BS1363A) (R449A) |
9032714.N1.05 | 200-230V/50-60Hz (CH Plug Type SEV 1011) (R290) |
9032714.S1.05 | 200-230V/50-60Hz (CH Plug Type SEV 1011) (R449A) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for MAGIO MS-450F
Downloads for MAGIO MS-450F
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureMAGIO MS-450F Benefits
Intelligent temperature control.
Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.
Many interfaces.
Straight-forward remote control, data management, and integration into process structures. USB, Ethernet, RS232, SD card, and alarm off are permanently integrated. Further interfaces available as accessories.
Touch display. Perfect operation.
With the touch display, the user always has an overview of all values and functions. The intuitive and multilingual menu structure enables perfect control.
Maximum safety.
Classification III according to DIN12876-1 enables safe operation, even with flammable fluids. Automatic switch-off in the event of high temperature or low liquid level.
Related Products
Products with similar properties