Calibration baths
for calibration of sensors, measuring instruments and thermometers
The JULABO calibration baths are perfectly suitable for applications in calibration laboratories and conform to the requirements specified by DIN ISO 9001. The instruments provide highest temperature stability to ±0.005 °C and temperature uniformity better than ±0.01 °C.
The series include models with cooling units for working temperature ranges from -30 to +200 °C as well as calibration baths for temperature ranges from +50 to +300 °C. Reference temperature measurements can be carried out with an additional precision reference sensor. This saves additional costs of a digital thermometer.
Product Features
- VFD COMFORT DISPLAY
- LCD DIALOG DISPLAY backlit for convenient interactive operation
- ICC (Intelligent Cascade Control), self-optimizing temperature control
- TCF Temperature Control Features to optimize the control behavior
- Integrated programmer for 6 x 60 program steps
- Highest temperature stability to ±0.005 °C (±0.02 °C at +200 °C)
- Temperature uniformity better than ±0.01 °C
- Optional Pt100 sensor for reference temperature measurements
- Temperature chamber with overflow at maximum liquid level
Product Overview
HighTech SL calibration baths
for working temperatures from +50 °C to +300 °C
![HighTech SL calibration bath SL-8K from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_qmva715qel06pao0khr6sbf478/-S96-FJPG/9352508-sl-8k-1.jpg)
JULABO calibration baths are ideal for high precision calibration of sensors, measuring instruments, thermometers, etc. The instruments are certified for application in DKD laboratories and according to the requirements specified by DIN EN ISO 9001:2000.
HighTech SL calibration baths
with integrated cooling machine for working temperatures up to -30 °C
![Calibration bath FK30-SL from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_sgeelb9mm55d72qlelfb7sgm3u/-S96-FJPG/9352627-fk30-sl-1.jpg)
The calibration baths in this category feature an integrated refrigeration unit and are suitable for calibration applications to -30 °C. The bath cover with openings and Viton® sleeves is already included in delivery for all models.
Model | Add to compare FK30-SL |
Add to compare FK31-SL |
---|---|---|
Working temperature range (°C) | -30 ... +200 | -30 ... +200 |
Temperature stability (°C) | ±0.005 | ±0.005 |
Cooling capacity (kW) | 0.46 | 0.46 |
Heating capacity (kW) | 2 | 2 |
Pump capacity flow pressure (l/min) | 22 ... 26 | 22 ... 26 |
Pump capacity pressure (bar) | 0.4 ... 0.7 | 0.4 ... 0.7 |