Calibration baths

for calibration of sensors, measuring instruments and thermometers

The JULABO calibration baths are perfectly suitable for applications in calibration laboratories and conform to the requirements specified by DIN ISO 9001. The instruments provide highest temperature stability to ±0.005 °C and temperature uniformity better than ±0.01 °C.

The series include models with cooling units for working temperature ranges from -30 to +200 °C as well as calibration baths for temperature ranges from +50 to +300 °C. Reference temperature measurements can be carried out with an additional precision reference sensor. This saves additional costs of a digital thermometer.

Product Features

  • VFD COMFORT DISPLAY
  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • Integrated programmer for 6 x 60 program steps
  • Highest temperature stability to ±0.005 °C (±0.02 °C at +200 °C)
  • Temperature uniformity better than ±0.01 °C
  • Optional Pt100 sensor for reference temperature measurements
  • Temperature chamber with overflow at maximum liquid level

Product Overview

HighTech SL calibration baths

for working temperatures from +50 °C to +300 °C

JULABO calibration baths are ideal for high precision calibration of sensors, measuring instruments, thermometers, etc. The instruments are certified for application in DKD laboratories and according to the requirements specified by DIN EN ISO 9001:2000.

Model
Add to compare
SL-14K
Add to compare
SL-8K
Working temperature range (°C) +50 ... +300 +50 ... +300
Temperature stability (°C) ±0.005 ±0.005
Heating capacity (kW) 3 3
Pump capacity flow pressure (l/min) 22 ... 26 22 ... 26
Pump capacity pressure (bar) 0.4 ... 0.7 0.4 ... 0.7

HighTech SL calibration baths

with integrated cooling machine for working temperatures up to -30 °C

The calibration baths in this category feature an integrated refrigeration unit and are suitable for calibration applications to -30 °C. The bath cover with openings and Viton® sleeves is already included in delivery for all models.

Model
Add to compare
FK30-SL
Add to compare
FK31-SL
Working temperature range (°C) -30 ... +200 -30 ... +200
Temperature stability (°C) ±0.005 ±0.005
Cooling capacity (kW) 0.46 0.46
Heating capacity (kW) 2 2
Pump capacity flow pressure (l/min) 22 ... 26 22 ... 26
Pump capacity pressure (bar) 0.4 ... 0.7 0.4 ... 0.7