PRESTO A80 Process system
2-stage process system for low temperatures
As air- or water-cooled versions, the units with 2-stage refrigeration unit offer high cooling and heating capacities for lowest temperatures down to -80 °C.
The highly dynamic temperature control systems PRESTO are designed for high-precision temperature control for a wide range of applications such as reactor vessels or material stress tests. Moreover, by using efficient components, the process systems can compensate exothermic and endothermic reactions exceptionally fast. Permanent internal monitoring and self-lubricating pumps ensure a long life-time. In addition, numerous interfaces offer many remote control possibilities across networks or for integration into higher-level control systems.
Order number including voltage version | see refrigerant variants |
---|---|
Working temperature range | -80 ... +250 °C |
Temperature stability | ±0.01 ... ±0.05 °C |
Heating capacity | 1.8 kW |
Pump capacity flow pressure | 0 ... 40 l/min |
Pump capacity pressure | 0.1 ... 1.7 bar |
Total dimensions
(W × L × H) |
43 x 65 x 126 cm |
Product Features
- Analog connections, RS485, Profibus DP (accessory)
- Space optimized design creates more room directly next to the units
- External Pt100 sensor connection
- Built-in 5.7’’ industrial color touchscreen
- Second external Pt100 sensor connection (accessory)
- Alarm output
- Temperature stability ±0.01 °C ... ±0.05 °C
- Pump pressure up to 1.7 bar, max. flow rate 40 l/min
- Heating capacity up to 3.4 kW
- Cooling capacity up to 1.2 kW
- removable ventilation grid
Technical data for PRESTO A80
Total dimensions (W × L × H) |
43 x 65 x 126 cm |
---|---|
Internal usable expansion volume | 5.6 l |
Minimal process volume | 3.9 l |
Active heat exchanger volume | 1.7 l |
Weight | 164 kg |
Pump connections | M24x1.5 male |
Working temperature range | -80 ... +250 °C |
---|---|
Temperature stability | ±0.01 ... ±0.05 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5 ... +40 °C |
Heating capacity | 1.8 kW | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 0 ... 40 l/min | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity pressure | 0.1 ... 1.7 bar | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Viscosity max. | 50 cSt | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power consumption | 16 A |
Cooling of compressor | 2-stage Air |
---|
Sound pressure level | 68 dbA |
---|---|
Classification according to DIN12876-1 |
Classification III (FL) |
IP Code according to IEC 60529 |
IP 20 |
Pump type | Centrifugal Pump (Magnetically coupled) |
Interfaces | Alarm output / Ethernet / Modbus TCP/IP / Profibus optional / REG/EPROG optional / RS232 / RS485 optional / SD memory card / Standby-Input optional / USB |
---|---|
External pt100 sensor connection | integrated |
2nd external Pt100 sensor connection | accessory |
Integrated programmer | 8x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | 5.7" TFT Touchscreen |
Temperature setting | Touchscreen |
9420801.03 | 230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R507) |
---|---|
9420801.S1.03 | 230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R449A) |
9420801.04 | 230V/50Hz (UK Plug Type BS1363A) (R507) |
9420801.14 | 208V/60Hz (Nema N6-20 Plug) (R507) |
Accessory for PRESTO A80
Downloads for PRESTO A80
We would also be happy to send you our printed catalogs and brochures by post.
Request brochurePRESTO A80 Benefits
Touch display. Perfect operation.
With the touch display, the user always has an overview of all values and functions. The intuitive and multilingual menu structure enables perfect control.
Convenience for several users
Administrator level for customizing instrument settings, user levels with limited permissions for fast and safe defined access, password protection, all levels adjustable
100 % Cooling capacity
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
Intelligent temperature control.
Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.
Related Products
Products with similar properties