CF30 Cryo-compact circulator
The cryo-compact circulators of the CF series provide powerful cooling and heating capabilities in a space-saving, compact design. The instruments feature 2 kW heating capacity and classification III according to DIN 12876-1. The cryo-compact circulators have pump connections for external temperature control applications and a bath opening for tem-perature control of small objects.
Performance data depends on the mains voltage in the country of use. Please select:
Order number including voltage version | 9400330.03 | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -30 ... +150 °C | |||||||||||||||||
Temperature stability | ±0.03 °C | |||||||||||||||||
Heating capacity | 2 kW | |||||||||||||||||
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||
Pump capacity flow pressure | 15 l/min | |||||||||||||||||
Pump capacity pressure | 0.35 bar | |||||||||||||||||
Usable bath opening (W x L / D) |
16 x 3 / 14 cm | |||||||||||||||||
Filling volume | 2 ... 3.5 l | |||||||||||||||||
Dimensions
(W × L × H) |
24 x 46 x 40 cm |
Product Features
- Ergonomic design and easy operation
- Small overall dimensions for lowest space requirement
- Splash-proof keypad
- Large, bright LED display
- Precise PID temperature control
- RS232 interface for PC connection
- Adjustable high temperature cut-out, visible via display
- Pump connections for external temperature applications
- Bath opening for temperature control of small objects in the bath
- Front drain
- Extra bright displays, easy to read from a distance
- Precise temperature control
- Unique early warning system for low liquid level
- ATC3 3-Point-Calibration
- Class III (FL) according to DIN 12876-1
Technical data for CF30
Dimensions (W × L × H) |
24 x 46 x 40 cm |
---|---|
Filling volume | 2 ... 3.5 l |
Weight | 35 kg |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | -30 ... +150 °C |
---|---|
Temperature stability | ±0.03 °C |
Temperature display resolution | 0.1 °C |
Ambient temperature | +5 ... +40 °C |
Performance data depends on the mains voltage in the country of use. Please select:
Heating capacity | 2 kW | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||
Pump capacity flow pressure | 15 l/min | |||||||||||||||||
Pump capacity pressure | 0.35 bar | |||||||||||||||||
Viscosity max. | 30 cSt | |||||||||||||||||
Power consumption | 10 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
16 x 3 / 14 cm |
Cooling of compressor | 1-stage Air |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 21 |
Pump type | Immersion Pump |
Temperature control | PID1 |
---|---|
Temperature display | LED |
9400330.13 | 230V/60Hz (Nema N6-20 Plug) (R134a) |
---|---|
9400330.02 | 115V/60Hz (Nema N5-20 Plug) (R134a) |
9400330.03 | 230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a) |
9400330.04 | 230V/50Hz (UK Plug Type BS1363A) (R134a) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for CF30
Downloads for CF30
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureCF30 Benefits
![Quality control](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_hevpr7dgr57jnafu373htsrb7e/-S65-FJPG/100-25-proofed.jpg)
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
![Environmentally friendly design for temperature control units](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_ps5rbagui16lf9opehta6id43r/-S65-FJPG/green-technology.jpg)
Green technology.
Development consistently applied environmentally friendly materials and technologies.
![Logo Made in Germany](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_faesup1da50v9aao0q9jbvr00g/-S65-FJPG/made-in-germany.jpg)
JULABO. Quality.
Highest standards of quality for a long product life.
![Quick guide for JULABO temperature control units](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_aoao523ptt7pjb16gkdbhpsq35/-S65-FJPG/quickstart.jpg)
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.
Related Products
Products with similar properties
![Cryo-compact circulator CF40 from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_884m9etac56rd1mfvfrbm1p96u/-S96-FJPG/9400340-cf40-1.jpg)
![Cryo-compact circulator CF31 from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_253ovtmq8d0fp0paclpopkjb4a/-S96-FJPG/9400331-cf31-1.jpg)
![Cryo-compact circulator CF41 from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_j0mun00t051en02406tbt2g04d/-S96-FJPG/9400341-cf41-1.jpg)