FT903 FT immersion cooler
with immersion probe for rapid cooling of liquids
JULABO immersion coolers are primarily used for counter-cooling when connected to a heating circulator, or for rapidly cooling fluids down to low temperatures. Take advantage of the space-saving design.
JULABO immersion coolers represent an economical alternative to conventional tap water cooling. The easy-to-use units are suitable for a variety of cooling applications.
Order number including voltage version | 9650893.33 |
---|---|
Working temperature range | -90 ... +30 °C |
Temperature stability | ±1 °C |
Total dimensions
(W × L × H) |
38 x 55 x 60 cm |
Product Features
- Rapid cooling of liquids down to low temperatures
- Counter-cooling of liquids in combination with heating circulators
- Preventing the use of precious tap water for cooling
- Compact design, small footprint
- Ease of operation
- Dry ice substitution
Technical data for FT903
Total dimensions (W × L × H) |
38 x 55 x 60 cm |
---|---|
Weight | 50 kg |
Working temperature range | -90 ... +30 °C |
---|---|
Temperature stability | ±1 °C |
Temperature display resolution | 0.1 °C |
Ambient temperature | +5 ... +40 °C |
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||||||
Power consumption | 6 A |
---|
Cooling of compressor | 2-stage Air |
---|
IP Code according to IEC 60529 |
IP 21 |
---|
External pt100 sensor connection | integrated |
---|---|
Temperature control | PID1 |
Temperature display | LED |
Temperature setting | Keypad |
Immersion probe type | inflexible |
---|---|
Dimensions cooling coil
(i.d. x o.d. x H) |
12 x 14 x 5.6 cm |
9650893.33 | 230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R404A) |
---|
Accessory for FT903
Downloads for FT903
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureFT903 Benefits
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
Green technology.
Development consistently applied environmentally friendly materials and technologies.
JULABO. Quality.
Highest standards of quality for a long product life.
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.
Related Products
Products with similar properties