CORIO CD-BT27 Heating circulator with open bath and transparent bath tanks

for internal and external applications at working temperatures from +20 °C to +100 °C

The open heating bath circulators of the new CORIO series feature high-quality transparent bath tanks and pump connections.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
CD-BT27
Order number including voltage version 9012327.02
Working temperature range 1 +20 ... +100 °C
Temperature stability ±0.03 °C
Heating capacity 1 kW
Pump capacity flow pressure 16 l/min
Pump capacity pressure 4.8 psi
Usable bath opening
(W x L / D)
11.8 x 13.8 / 7.9 in.
Filling volume 20 ... 27 l
Total dimensions
(W × L × H)
15 x 22.8 x 16.9 in.

1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.

Arrange callback

Product Features

  • Bright, white, easy to read display
  • Very quiet
  • easy switching between internal and external circulation
  • USB connection
  • Class III (FL) according to DIN 12876-1
  • For internal and external applications

Technical data for CORIO CD-BT27

Dimensions and volumes
Total dimensions
(W × L × H)
15 x 22.8 x 16.9 in.
Filling volume 20 ... 27 l
Weight 17.9 lbs
Pump connections M16x1 male
Barbed fittings inner diameter 8/12 mm
Temperature values
Working temperature range 1 +20 ... +100 °C
Temperature stability ±0.03 °C
Setting the resolution of the temperature display 0.1 °C
Temperature display resolution 0.01 ... 0.1 °C
Ambient temperature +5 ... +40 °C

1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 1 kW
Pump capacity flow pressure 16 l/min
Pump capacity pressure 4.8 psi
Viscosity max. 50 cSt
Power consumption 10 A
Bath
Bath tank Polycarbonat
Bath cover accessory
Usable bath opening
(W x L / D)
11.8 x 13.8 / 7.9 in.
Cooling
Cooling coil accessory
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump function Pressure Pump
Pump type Immersion Pump
Electronics
Interfaces USB
Temperature control PID1
Absolute temperature calibration 1 Point Calibration
Temperature display LED
Temperature setting Keypad
Available voltage versions
9012327.01 100V/50-60Hz (Nema N5-15 Plug)
9012327.02 115V/60Hz (Nema N5-15 Plug)
9012327.03 230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
9012327.03.chn 230V/50Hz (CN Plug)
9012327.04 230V/50Hz (UK Plug Type BS1363A)
9012327.05 230V/50Hz (CH Plug Type SEV 1011)
9012327.13 230V/60Hz (Nema N5-15 Plug)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
Contact expert

Heat-up time

Medium: Water

Pump capacity

Medium: Water

Accessory for CORIO CD-BT27

Downloads for CORIO CD-BT27

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

CORIO CD-BT27 Benefits

Brilliant.

Very bright display makes it easy to read even from a distance.

Timer. Integrated.

CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes.

Connection. Easy.

Inclined pump connections (M16×1) facilitate the connection of applications. Each unit includes 2 barbed fittings of 8/12 mm diameter each.

Everything at the front.

All operating controls and safety functions are accessed easily and comfortably from the front.

Show all 19 benefits

JULABO customer survey

We appreciate if you take part and help us to further improve. The survey takes only 3 minutes and is anonymous. Thank you!

Compare products