Ultra-Low Refrigerated-Heating Circulators
for working temperatures from -95 °C to +150 °C
JULABO Ultra-Low Refrigerated Circulators for heating and cooling. The units are suitable for external temperature applications with simultaneous operation in the bath tank. The units provide particularly high heating and cooling capacities for rapid heat-up and cool-down times even for large volume, external systems.
‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Models with the designation ‚W‘ are water-cooled. With handle or castors to allow easy transport. With drain port for conveniently draining the bath fluid. The units offer an improved insulation to prevent ice-formation and have a filling level display. Typical applications: Temperature applications to jacketed reaction vessels, autoclaves, miniplant installations, kilo labs, freezing point determination, calibration at low temperatures, petroleum testing, etc.
Product Features
- VFD COMFORT DISPLAY
- Keypad for setpoints, warning/safety values and menu functions
- Pt100 External sensor connection for measurement and control
- SMART PUMP, electronically adjustable pump stages
- Adjustable high temperature cut-out, visible via display
- Active Cooling Control
Product Overview
HighTech SL/HL Ultra-Low Refrigerated / Heating Circulators
low temperatures below -50 °C for internal and external applications
The Ultra-Low Refrigerated Circulators of the HighTech Series with HL or SL circulator feature powerful pressure and suction pumps. The instruments provide the entire variety of functions of the professional HighTech Series of circulators.
Model | Add to compare FP52-SL |
Add to compare FPW52-SL |
Add to compare FP55-SL |
Add to compare FPW55-SL |
---|---|---|---|---|
Working temperature range (°C) | -55 ... +100 | -55 ... +100 | -55 ... +100 | -55 ... +100 |
Temperature stability (°C) | ±0.05 | ±0.05 | ±0.05 | ±0.05 |
Cooling capacity (kW) | 3 | 3 | 5.2 | 5.2 |
Heating capacity (kW) | 3 | 3 | 3 | 3 |
Pump capacity flow pressure (l/min) | 22 ... 26 | 22 ... 26 | 22 ... 26 | 22 ... 26 |
Pump capacity pressure (psi) | 5.8 ... 10.2 | 5.8 ... 10.2 | 5.8 ... 10.2 | 5.8 ... 10.2 |
Model | Add to compare F81-HL |
Add to compare FP89-HL |
Add to compare FP90-SL |
Add to compare FPW90-SL |
---|---|---|---|---|
Working temperature range (°C) | -81 ... +100 | -90 ... +100 | -90 ... +100 | -90 ... +100 |
Temperature stability (°C) | ±0.02 | ±0.02 | ±0.05 | ±0.05 |
Cooling capacity (kW) | 0.45 | 0.85 | 1.8 | |
Heating capacity (kW) | 1.3 | 1.3 | 3 | |
Pump capacity flow pressure (l/min) | 22 ... 26 | 22 ... 26 | 22 ... 26 | |
Pump capacity pressure (psi) | 5.8 ... 10.2 | 5.8 ... 10.2 | 5.8 ... 10.2 |
Model | Add to compare FPW91-SL |
---|---|
Working temperature range (°C) | -91 ... +100 |
Temperature stability (°C) | ±0.2 |
() | |
() | |
() | |
() |
TopTech ME Ultra-Low Refrigerated / Heating Circulators
Ultra-low Refrigerated Circulator with 2-stage cascade-cooling
The Ultra-Low Refrigerated Circulators of the TopTech Series are equipped with a dual-stage cascade refrigeration system for continuous operation of internal and external temperature applications.
Model | Add to compare F81-ME |
Add to compare FP89-ME |
---|---|---|
Working temperature range (°C) | -81 ... +100 | -90 ... +100 |
Temperature stability (°C) | ±0.02 | ±0.02 |
Cooling capacity (kW) | 0.45 | 1 |
Heating capacity (kW) | 1.2 | 1.2 |
Pump capacity flow pressure (l/min) | 11 ... 16 | 11 ... 16 |
Pump capacity pressure (psi) | 3.3 ... 6.5 | 3.3 ... 6.5 |
HighTech SL Ultra-Low Refrigerated / Heating Circulators
with filling port upgradeable with additional heating and pump capacity for external control only
Ultra-Low Refrigerated Circulators with SL circulator impress with their high heating, cooling and pump capacities for external temperature control applications.
Model | Add to compare FP52-SL |
Add to compare FP52-SL |
Add to compare FPW52-SL |
Add to compare FPW52-SL |
---|---|---|---|---|
Working temperature range (°C) | -55 ... +100 | -55 ... +150 | -55 ... +100 | -55 ... +150 |
Temperature stability (°C) | ±0.05 | ±0.05 | ±0.05 | ±0.05 |
Cooling capacity (kW) | 3 | 3 | 3 | 3 |
Heating capacity (kW) | 3 | 3 | 3 | 3 |
Pump capacity flow pressure (l/min) | 22 ... 26 | 22 ... 26 | 22 ... 26 | 22 ... 26 |
Pump capacity pressure (psi) | 5.8 ... 10.2 | 5.8 ... 10.2 | 5.8 ... 10.2 | 5.8 ... 10.2 |
Model | Add to compare FP55-SL |
Add to compare FP55-SL |
Add to compare FPW55-SL |
Add to compare FPW55-SL |
---|---|---|---|---|
Working temperature range (°C) | -55 ... +100 | -55 ... +150 | -55 ... +100 | -55 ... +150 |
Temperature stability (°C) | ±0.05 | ±0.05 | ±0.05 | ±0.05 |
Cooling capacity (kW) | 5.2 | 5.2 | 5.2 | 5.2 |
Heating capacity (kW) | 3 | 3 | 3 | 3 |
Pump capacity flow pressure (l/min) | 22 ... 26 | 22 ... 26 | 22 ... 26 | 22 ... 26 |
Pump capacity pressure (psi) | 5.8 ... 10.2 | 5.8 ... 10.2 | 5.8 ... 10.2 | 5.8 ... 10.2 |
Model | Add to compare FP90-SL |
Add to compare FP90-SL |
Add to compare FPW90-SL |
Add to compare FPW90-SL |
---|---|---|---|---|
Working temperature range (°C) | -90 ... +100 | -90 ... +150 | -90 ... +100 | -90 ... +150 |
Temperature stability (°C) | ±0.05 | ±0.05 | ±0.05 | ±0.05 |
Cooling capacity (kW) | 1.8 | 1.8 | 1.8 | |
Heating capacity (kW) | 3 | 3 | 3 | |
Pump capacity flow pressure (l/min) | 22 ... 26 | 22 ... 26 | 22 ... 26 | |
Pump capacity pressure (psi) | 5.8 ... 10.2 | 5.8 ... 10.2 | 5.8 ... 10.2 |
MAGIO MS Ultra-low refrigerated / heating circulators
with extremely powerful pressure and suction pump, intuitive touch display and for lowest temperatures until -90 °C
As with all circulators from the MAGIO range, the ultra-low refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. The devices offer extra strong pressure and suction pumps, thus fulfilling the highest demands for temperature control of external applications. They cover an enormous temperature range and are also suitable for simulating extreme conditions down to -90 °C.
Model | Add to compare MAGIO MS-1000FF |
---|---|
Working temperature range (°C) | -90 ... +100 |
Temperature stability (°C) | 0.02 |
Cooling capacity (kW) | 1.25 |
Heating capacity (kW) | 1.8 |
Pump capacity flow pressure (l/min) | 16 ... 31 |
Pump capacity pressure (psi) | 3.5 ... 13.3 |