Working temperature range
1
+20 ... +100 °C
Temperature stability
±0.03 °C
Heating capacity
2 kW
Pump capacity flow pressure
15 l/min
Pump capacity pressure
0.35 bar
Usable bath opening(W x L / D)
30 x 35 / 20 cm
Filling volume
20 ... 27 l
Total dimensions
(W × L × H)
38 x 58 x 43 cm
1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.
Bright, white, easy to read display
Very quiet
easy switching between internal and external circulation
USB connection
Class III (FL) according to DIN 12876-1
For internal and external applications
Technical data for CORIO CD-BT27
Dimensions and volumes
Total dimensions(W × L × H)
38 x 58 x 43 cm
Filling volume
20 ... 27 l
Weight
8.1 kg
Pump connections
M16x1 male
Barbed fittings inner diameter
8/12 mm
Temperature values
Working temperature range
1
+20 ... +100 °C
Temperature stability
±0.03 °C
Setting the resolution of the temperature display
0.1 °C
Temperature display resolution
0.01 ... 0.1 °C
Ambient temperature
+5 ... +40 °C
1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.
Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity
2 kW
Pump capacity flow pressure
15 l/min
Pump capacity pressure
0.35 bar
Viscosity max.
50 cSt
Power consumption
10 A
Bath
Bath tank
Polycarbonat
Bath cover
accessory
Usable bath opening(W x L / D)
30 x 35 / 20 cm
Cooling
Cooling coil
accessory
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump function
Pressure Pump
Pump type
Immersion Pump
Electronics
Interfaces
USB
Temperature control
PID1
Absolute temperature calibration
1 Point Calibration
Temperature display
LED
Temperature setting
Keypad
Available voltage versions
9012327.01
100V/50-60Hz (Nema N5-15 Plug)
9012327.02
115V/60Hz (Nema N5-15 Plug)
9012327.03
230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F)
9012327.03.chn
230V/50Hz (CN Plug)
9012327.04
230V/50Hz (UK Plug Type BS1363A)
9012327.05
230V/50Hz (CH Plug Type SEV 1011)
9012327.13
230V/60Hz (Nema N5-15 Plug)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
Add to quotation request
Contact expert
Heat-up time
Medium: Water
Pump capacity
Medium: Water
Accessory for CORIO CD-BT27
Downloads for CORIO CD-BT27
We would also be happy to send you our printed catalogs and brochures by post.
Request brochure