DYNEO DD-200F Refrigerated / heating circulator
New temperature control technology for demanding applications
Refrigerated circulators of the DYNEO series distinguish themselves with a great price-performance ratio. The instruments offer high heating/cooling capacities for short heat-up and cool-down times. The refrigerated circulators work precisely and reliably even at higher ambient temperatures up to +40 °C. Either in basic research, in material testing or in technical systems – the DYNEO refrigerated circulators offer functional solutions for every requirement and budget.
With a working temperature range of -20 ... +200 °C, the Refrigerated / heating circulator DYNEO DD-200F delivers an outstanding cooling capacity of kW at 20°C despite its compact design. The optimized design of the bath tank and cooling coil makes the bath more spacious and user-friendly for the operator. Ventilation slots and connections are located on the front and rear, allowing several units to be placed next to each other in order to save space.
![Digital and analog interfaces for DYNEO laboratory circulators](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_ok2ousbib56a39ihkftakstp1v/-S65-FJPG/dyneo-options-analogue-or-ditigal-interface.jpg)
Optional analog and digital interface
DYNEO circulators can optionally be equipped with analogue or digital interfaces. To request the options, order number must be extended with .d for the digital and .a for the analog interface (9XXX XXXX.A / 9XXX XXX.D)
Performance data depends on the mains voltage in the country of use. Please select:
Order number including voltage version | see refrigerant variants | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -20 ... +200 °C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature stability | ±0.01 °C | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Heating capacity | 2 kW | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 8 ... 27 l/min | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity pressure | 0.1 ... 0.7 bar | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Usable bath opening (W x L / D) |
13 x 15 / 15 cm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Filling volume | 3 ... 4 l | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions
(W × L × H) |
23 x 39 x 65 cm |
Product Features
- Optimized cooling coil design saves space in the bath tank
- powerful and infinitely adjustable pressure pump
- Flow rate 27 l/min, pressure 0.7 bar
- easy switching between internal and external circulation
- large color TFT display, multilingual interface
- central rotary knob (controller) simplifies operation
- Integrated programmer
- Integrated external Pt100 connection
- USB connection
- RS232 interface or analog interfaces (optional)
- integrated drain makes emptying liquid easy and safe.
- Bath cover included with delivery
- removable ventilation grid
- Powerful cooling machines
- For internal and external applications
- Integrated pump connection M16×1
- For internal and external applications
Technical data for DYNEO DD-200F
Dimensions (W × L × H) |
23 x 39 x 65 cm |
---|---|
Filling volume | 3 ... 4 l |
Weight | 25.7 kg |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | -20 ... +200 °C |
---|---|
Temperature stability | ±0.01 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5 ... +40 °C |
Performance data depends on the mains voltage in the country of use. Please select:
Heating capacity | 2 kW | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 8 ... 27 l/min | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity pressure | 0.1 ... 0.7 bar | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Viscosity max. | 50 cSt | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power consumption | 12 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
13 x 15 / 15 cm |
Cooling of compressor | 1-stage Air |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 21 |
Pump function | Pressure Pump |
Pump type | Immersion Pump |
User Interface Language | Chinese / English / French / German / Italian / Japanese / Korean / Portuguese / Russian / Spanish |
Interfaces | Alarm output optional / REG/EPROG optional / RS232 optional / Standby-Input optional / USB |
---|---|
External pt100 sensor connection | integrated |
Integrated programmer | 8x60 steps |
Temperature control | PID3 |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | 3.5" TFT Display |
Temperature setting | Shaft Encoder |
Electronic Timer h:min |
00:00 ... 99:59 |
9021701.33.chn | 230V/50-60Hz (CN Plug) (R134a) |
---|---|
9021701.N1.33.chn | 230V/50-60Hz (CN Plug) (R290) |
9021701.33 | 230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a) |
9021701.N1.33 | 230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R290) |
9021701.05 | 230V/50-60Hz (CH Plug Type SEV 1011) (R134a) |
9021701.N1.05 | 230V/50-60Hz (CH Plug Type SEV 1011) (R290) |
9021701.04 | 230V/50-60Hz (UK Plug Type BS1363A) (R134a) |
9021701.N1.04 | 230V/50-60Hz (UK Plug Type BS1363A) (R290) |
9021701.02 | 115V/60Hz (Nema N5-15 Plug) (R134a) |
9021701.N1.02 | 115V/60Hz (Nema N5-15 Plug) (R290) |
9021701.01 | 100V/50-60Hz (Nema N5-15 Plug) (R134a) |
9021701.N1.01 | 100V/50-60Hz (Nema N5-15 Plug) (R290) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for DYNEO DD-200F
Downloads for DYNEO DD-200F
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureDYNEO DD-200F Benefits
![Laboratory circulator with castors and handles for simple maneuvering](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_m8c53s42v54ft70mepsqn14i7i/-S65-FJPG/easy-to-handle.jpg)
Handle with ease.
Makes day-to-day work easy. Comfortably move your JULABO Circulator around by using the ergonomic handles (front and rear).
![Icon: PID 2](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_4vokhgm76908v1coeahgkbsr6u/-S65-FJPG/pid2.jpg)
Highly precise
PID Temperature control with drift compensation and adjustable control parameters, temperature stability ±0.01...±0.02 °C
![JULABO DYNEO laboratory circulators](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_mff17srrvp7hle287t40jgpf0l/-S65-FJPG/dyneo-dd300f-ddbc26-dd600f-19.jpg)
Wide range.
Refrigerated and heating circulator in various combinations, circulator in various sizes. Maximum flexibility through a large selection of accessories.
![Display JULABO DYNEO laboratory circulator](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_mg94bcgaih0rteim1hvhnufu46/-S65-FJPG/brilliantes-tft-display.jpg)
Brilliance. In color.
Large color display with vivid luminance is easy to read, even from a large distance.
Related Products
Products with similar properties
![Refrigerated / heating circulator CORIO CD-201F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_9acrj1rvih45p6g7hpdkkcud4r/-S96-FJPG/9012702-corio-cd-201f-1.jpg)
![Refrigerated / heating circulator CORIO CP-201F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_bvl5kqn3tl6rp2r1t05648m15j/-S96-FJPG/9013702-corio-cp-201f-1.jpg)
![Refrigerated / heating circulator DYNEO DD-201F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_dunb4qhfb55bb41rmg5e127834/-S96-FJPG/9021702-dyneo-dd-201f-1.jpg)
![Refrigerated / heating circulator DYNEO DD-300F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_6mbrel38hd0up2p9rjk5d12p30/-S96-FJPG/9021703-dyneo-dd-300f-1.jpg)