PRESTO process systems

working temperature range -93 °C to +250 °C

An entirely new generation of highly dynamic temperature control systems by JULABO. The new PRESTO systems are designed for precise temperature control as well as rapid temperature changes, making them ideal for reactor vessels, material stress tests, or temperature simulations. These instruments cover a working temperature of -93 to +250 °C with high cooling and heating capacity.

Highly efficient components give these instruments the ability to compensate for exothermic and endothermic reactions with extraordinary speed. Permanent internal monitoring and self-lubricating pumps contribute to the new PRESTO’s long service life. The integrated 5.7-inch color industrial-grade touch panel is one of the identifying characteristics of the new PRESTO. It gives the user a clear and well-organized view of important information while greatly improving user-friendliness. Once in operation, the new PRESTO® units are whisper quiet and barely audible in a laboratory. The new PRESTO® units are extremely robust and work reliably even if the ambient temperature climbs as high as +40 °C. Multiple interfaces permit remote control of the PRESTO® across networks and in superordinated control systems. Closed side panels without ventilation slits reduces to a minimum the amount of space needed to operate.

Product Features

  • For highly precise, external temperature applications
  • Rapid heating and cooling
  • Wide working temperature ranges without changing fluids
  • Highest performance with small footprint
  • Space-saving design optimizes space utilization in your lab
  • Ethernet interface
  • SD-Card slot
  • Highly dynamic ICC temperature control, stability to ±0.01 °C
  • Electronic level indication
  • Integrated programmer
  • Unsurpassed power and efficiency
  • Profibus DP (Accessory)

Product Overview

PRESTO A30/A38/A40/W40/A41/W41

Compact process systems down to -45 °C

The smaller PRESTO process systems are available with natural or synthetic refrigerants, depending on the model, and cover a working temperature range from -45 °C to +250 °C.

Model
Add to compare
PRESTO A30
Add to compare
PRESTO A40
Add to compare
PRESTO A38
Add to compare
PRESTO A41
Working temperature range (°C) -30 ... +250 -40 ... +250 -45 ... +250 -45 ... +250
Temperature stability (°C) ±0.01 ... ±0.05 ±0.01 ... ±0.05 ±0.01 ... ±0.05 ±0.01 ... ±0.05
Cooling capacity (kW) 0.5 1.2 0.91 1.47
Heating capacity (kW) 2.7 2.7 2.7 2.7
Pump capacity flow pressure (l/min) 25 0 ... 40 0 ... 50 0 ... 50
Pump capacity pressure (bar) 0.5 0.1 ... 1.7 0.1 ... 1.6 0.1 ... 1.6
Model
Add to compare
PRESTO W40
Add to compare
PRESTO W41
Working temperature range (°C) -40 ... +250 -45 ... +250
Temperature stability (°C) ±0.01 ... ±0.05 ±0.01 ... ±0.05
Cooling capacity (kW) 1.2 1.47
Heating capacity (kW) 2.7 2.7
Pump capacity flow pressure (l/min) 0 ... 40 0 ... 50
Pump capacity pressure (bar) 0.1 ... 1.7 0.1 ... 1.6

PRESTO A45/A45t

Air-cooled process systems down to -45 °C

The A45 air-cooled process system can be used flexibly and independently of cooling water supply. They compensate exothermic and endothermic reactions extremely quickly.

Model
Add to compare
PRESTO A45
Add to compare
PRESTO A45t
Working temperature range (°C) -45 ... +250 -45 ... +250
Temperature stability (°C) ±0.05 ... ±0.1 ±0.05 ... ±0.1
Cooling capacity (kW) 3.5 3.5
Heating capacity (kW) 6 12
Pump capacity flow pressure (l/min) 0 ... 80 0 ... 80
Pump capacity pressure (bar) 0.1 ... 3 0.1 ... 3

PRESTO W50/W50t

Water-cooled process system down to -50 °C

The rapid compensation of reactions even at higher ambient temperatures is the domain of the water-cooled W50 units. High heating and cooling capacity paired with powerful pumps.

Model
Add to compare
PRESTO W50
Add to compare
PRESTO W50t
Working temperature range (°C) -50 ... +250 -50 ... +250
Temperature stability (°C) ±0.05 ... ±0.1 ±0.05 ... ±0.1
Cooling capacity (kW) 7.5 7.5
Heating capacity (kW) 6 12
Pump capacity flow pressure (l/min) 0 ... 80 0 ... 80
Pump capacity pressure (bar) 0.1 ... 3 0.1 ... 3

PRESTO W55

Fast temperature control for larger applications

The powerful W55 regulates temperatures with high precision and convinces with faster cool-down and heat-up times. It is ideal for use in large external applications such as reactor temperature control, material stress testing or temperature simulation.

Model
Add to compare
PRESTO W55
Working temperature range (°C) -55 ... +250
Temperature stability (°C) ±0.05 ... ±0.1
Cooling capacity (kW) 15
Heating capacity (kW) 15
Pump capacity flow pressure (l/min) 0 ... 80
Pump capacity pressure (bar) 0.1 ... 3

PRESTO W56/W58

The most powerful, single-stage, highly dynamic temperature control systems

The water-cooled PRESTO W56, W56x, and W58x can temperature control applications with high performance requirements very quickly and efficiently. Even at low temperatures, these models have large power reserves for demanding external applications.

Model
Add to compare
PRESTO W56
Add to compare
PRESTO W56x
Add to compare
PRESTO W58x
Working temperature range (°C) -56 ... +250 -50 ... +250 -50 ... +250
Temperature stability (°C) ±0.05 ... ±0.1 ±0.05 ... ±0.1 ±0.05 ... ±0.1
Cooling capacity (kW) 25.8 25.8 33
Heating capacity (kW) 27 27 27
Pump capacity flow pressure (l/min) 0 ... 80 0 ... 70 0 ... 70
Pump capacity pressure (bar) 0.1 ... 3 0.1 ... 5.5 0.1 ... 5.5

PRESTO A70/A80/W80

2-stage process system for low temperatures

As air- or water-cooled versions, the units with 2-stage refrigeration unit offer high cooling and heating capacities for lowest temperatures down to -80 °C.

Model
Add to compare
PRESTO A70
Add to compare
PRESTO A80
Add to compare
PRESTO W80
Add to compare
PRESTO A80t
Working temperature range (°C) -75 ... +250 -80 ... +250 -80 ... +250 -80 ... +250
Temperature stability (°C) ±0.01 ... ±0.05 ±0.01 ... ±0.05 ±0.01 ... ±0.05 ±0.01 ... ±0.05
Cooling capacity (kW) 1.12 1.2 1.2 1.2
Heating capacity (kW) 1.8 1.8 1.8 3.4
Pump capacity flow pressure (l/min) 0 ... 40 0 ... 40 0 ... 40 0 ... 40
Pump capacity pressure (bar) 0.1 ... 1.7 0.1 ... 1.7 0.1 ... 1.7 0.1 ... 1.7
Model
Add to compare
PRESTO W80t
Working temperature range (°C) -80 ... +250
Temperature stability (°C) ±0.01 ... ±0.05
Cooling capacity (kW) 1.2
Heating capacity (kW) 3.4
Pump capacity flow pressure (l/min) 0 ... 40
Pump capacity pressure (bar) 0.1 ... 1.7

PRESTO A85/A85t/W85/W85t

Powerhouses among the process system

High cooling capacities enable extremely low temperatures down to -85 °C possible. The high heating capacity, particularly with the A85t and the W85t, provides even more flexibility in the application.

Model
Add to compare
PRESTO A85
Add to compare
PRESTO W85
Add to compare
PRESTO A85t
Add to compare
PRESTO W85t
Working temperature range (°C) -85 ... +250 -85 ... +250 -85 ... +250 -85 ... +250
Temperature stability (°C) ±0.05 ... ±0.1 ±0.05 ... ±0.1 ±0.05 ... ±0.1 ±0.05 ... ±0.1
Cooling capacity (kW) 2.5 2.8 2.5 2.8
Heating capacity (kW) 6 6 15 15
Pump capacity flow pressure (l/min) 0 ... 80 0 ... 80 0 ... 80 0 ... 80
Pump capacity pressure (bar) 0.1 ... 3 0.1 ... 3 0.1 ... 3 0.1 ... 3

PRESTO W91

11 kW cooling capacity for dynamic temperature change down to -91 °C

Best heating capacity combined with high cooling capacity – those are the key features of the W91 units. The units are just as ready for embedding into pilot plants as they are for use in material and component testing.

Model
Add to compare
PRESTO W91tt
Add to compare
PRESTO W91x
Add to compare
PRESTO W91ttx
Add to compare
PRESTO W91
Working temperature range (°C) -91 ... +250 -91 ... +250 -91 ... +250 -91 ... +250
Temperature stability (°C) ±0.05 ... ±0.2 ±0.05 ... ±0.2 ±0.05 ... ±0.2 ±0.05 ... ±0.2
Cooling capacity (kW) 11 11 11 11
Heating capacity (kW) 36 18 36 18
Pump capacity flow pressure (l/min) 0 ... 80 0 ... 70 0 ... 70 0 ... 80
Pump capacity pressure (bar) 0.1 ... 3 0.1 ... 5.5 0.1 ... 5.5 0.1 ... 3

PRESTO W92

Highest cooling capacity of 27 kW and heating capacity up to 36 kW

The W92 class process systems are extremely powerful and can also simulate extreme environmental conditions. They are used, for example, in the temperature control of vacuum chambers for component testing in the aerospace industry.

Model
Add to compare
PRESTO W92tt
Add to compare
PRESTO W92x
Add to compare
PRESTO W92
Add to compare
PRESTO W92ttx
Working temperature range (°C) -92 ... +250 -92 ... +250 -92 ... +250 -92 ... +250
Temperature stability (°C) ±0.05 ... ±0.2 ±0.05 ... ±0.2 ±0.05 ... ±0.2 ±0.05 ... ±0.2
Cooling capacity (kW) 27 27 27 27
Heating capacity (kW) 36 18 18 36
Pump capacity flow pressure (l/min) 0 ... 80 0 ... 70 0 ... 80 0 ... 70
Pump capacity pressure (bar) 0.1 ... 3 0.1 ... 5.5 0.1 ... 3 0.1 ... 5.5

PRESTO W93

Full cooling capacity in the low temperature range

W93 process systems offer users high cooling capacity for dynamic applications even in the lowest temperature ranges. They work with natural refrigerants and are also very energy efficient thanks to state-of-the-art technologies.

Model
Add to compare
PRESTO W93
Add to compare
PRESTO W93x
Working temperature range (°C) -93 ... +250 -93 ... +250
Temperature stability (°C) ±0.05 ... ±0.2 ±0.05 ... ±0.2
Cooling capacity (kW) 21.5 21
Heating capacity (kW) 27 27
Pump capacity flow pressure (l/min) 0 ... 80 0 ... 70
Pump capacity pressure (bar) 0.1 ... 3 0.1 ... 5.5

JULABO customer survey

We appreciate if you take part and help us to further improve. The survey takes only 3 minutes and is anonymous. Thank you!

Compare products