CORIO CP-449F Refrigerated / heating circulator
with an enhanced pump performance and a temperature range up to +200 °C
Refrigerated circulators from the CORIO CP range are suitable for applications with a temperature range up to +200°C. The enhanced pump performance ensures they are suitable for easy temperature control tasks in combination with external applications.
The CORIO CP-449F refrigerated circulator has an exceptionally large bath volume. This makes the unit ideal for precisely tempering larger or a variety of different samples in the bath.
![Icon Energieeffizienz](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_ol6l12pkat30l0oe1rvma1vr1e/-S65-FJPG/icon-energieeffizienz.jpg)
Energy-efficient temperature control
You can really save money with our energy-efficient refrigerated circulators. Thanks to speed-controlled components, power consumption is significantly reduced. This reduces electricity costs by up to 70% over the entire product life cycle. By minimizing energy requirements, you also make a positive contribution to protecting the environment.
Performance data depends on the mains voltage in the country of use. Please select:
Order number including voltage version | 9013716.N1.33 |
---|---|
Working temperature range | -32 ... +200 °C |
Temperature stability | ±0.03 °C |
Heating capacity | 2 kW |
Pump capacity flow pressure | 8 ... 27 l/min |
Pump capacity pressure | 0.1 ... 0.7 bar |
Usable bath opening (W x L / D) |
28 x 35 / 20 cm |
Filling volume | 20 ... 26 l |
Total dimensions
(W × L × H) |
37 x 59 x 69 cm |
Product Features
- Models for internal and external applications
- Bright, white, easy to read display
- Very quiet
- powerful and infinitely adjustable pressure pump
- USB connection
- RS232 interface for online communication
- Bath lid and drain tap included
- removable ventilation grid
- Refrigeration unit without side vents
- Class III (FL) according to DIN 12876-1
- easy switching between internal and external circulation
- Integrated pump connection M16×1
- Space-saving cooling coil design yields more usable space in the bath tank
- early warning system for low liquid level
Technical data for CORIO CP-449F
Total dimensions (W × L × H) |
37 x 59 x 69 cm |
---|---|
Filling volume | 20 ... 26 l |
Weight | 39.5 kg |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | -32 ... +200 °C |
---|---|
Temperature stability | ±0.03 °C |
Setting the resolution of the temperature display | 0.1 °C |
Temperature display resolution | 0.01 ... 0.1 °C |
Ambient temperature | +5 ... +40 °C |
Performance data depends on the mains voltage in the country of use. Please select:
Heating capacity | 2 kW | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||||
Pump capacity flow pressure | 8 ... 27 l/min | |||||||||||||||||||||
Pump capacity pressure | 0.1 ... 0.7 bar | |||||||||||||||||||||
Viscosity max. | 50 cSt | |||||||||||||||||||||
Power consumption | 12 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
28 x 35 / 20 cm |
Cooling of compressor | 1-stage Air |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 21 |
Pump function | Pressure Pump |
Pump type | Immersion Pump |
Interfaces | RS232 / USB |
---|---|
Temperature control | PID1 |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | LED |
Temperature setting | Keypad |
Electronic Timer h:min |
0 ... 999 |
9013716.N1.22 | 100-115V/50-60Hz (Nema N5-15 Plug) (R290) |
---|---|
9013716.N1.33 | 200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R290) |
9013716.N1.33.chn | 200-230V/50-60Hz (CN Plug) (R290) |
9013716.N1.04 | 200-230V/50-60Hz (UK Plug Type BS1363A) (R290) |
9013716.N1.05 | 200-230V/50-60Hz (CH Plug Type SEV 1011) (R290) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for CORIO CP-449F
Downloads for CORIO CP-449F
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureCORIO CP-449F Benefits
![Brilliant display of a laboratory circulator, easy to read](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_vsgu96pbkd00r4nl724es4i85p/-S65-FJPG/brilliant-display.jpg)
Brilliant.
Very bright display makes it easy to read even from a distance.
![CORIO laboratory circulators, adjusting the temperature](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_ku2sr6rap15apettufbqdj2s4p/-S65-FJPG/switch-on-start.jpg)
Switch on. And off you go.
Intelligent operating concept. Ready for operation with just a few quick and easy steps.
![Laboratory circulator with timer function](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_uf71gcavo52c19vhakp0io694c/-S65-FJPG/timer-function.jpg)
Timer. Integrated.
CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes.
![Easy access filling Laboratory circulator](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_c4h0udnq4p1l3606fusug8ka0u/-S65-FJPG/all-in-front.jpg)
Everything at the front.
All operating controls and safety functions are accessed easily and comfortably from the front.
Related Products
Products with similar properties
![Refrigerated / heating circulator CORIO CD-300F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_2pnt471db907nfsotrsslci90r/-S277-FJPG/9012703-corio-cd-300f-1.jpg)
![Refrigerated / heating circulator DYNEO DD-300F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_6mbrel38hd0up2p9rjk5d12p30/-S277-FJPG/9021703-dyneo-dd-300f-1.jpg)
![Refrigerated / heating circulator CORIO CP-201F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_bvl5kqn3tl6rp2r1t05648m15j/-S277-FJPG/9013702-corio-cp-201f-1.jpg)
![Refrigerated / heating circulator CORIO CP-600F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_mebr1h81ll2fvel1hj2fqqkj1j/-S277-FJPG/9013704-corio-cp-600f-1.jpg)