DYNEO DD-1001F-BF
Order number including voltage version |
9021709.33.D |
Working temperature range
|
-38 ... +100 °C
|
Temperature stability
|
±0.01 °C
|
Heating capacity
|
2 kW
|
Cooling capacity
°C |
20 |
10 |
0 |
-10 |
-20 |
-30 |
kW
1
|
1 |
0.95 |
0.85 |
0.6 |
0.32 |
0.12 |
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
|
Pump capacity flow pressure
|
8 ... 27 l/min
|
Pump capacity pressure
|
0.1 ... 0.7 bar
|
Usable bath opening (W x L / D) |
35 x 41 / 30 cm
|
Filling volume
|
48 ... 56 l
|
Dimensions
(W × L × H) |
45 x 64 x 95 cm
|
- Automatic cycles of temperature ramps simulate aging
- Pre-programmed temperature profiles for forcing test
- Program modification possible at any time
- Large bath opening with insert for 20 bottles, 0.5 liters each (Racks for other bottle sizes on request)
- Removable Plexiglass® cover
- RS232 interface for online communication
- powerful and infinitely adjustable pressure pump
- Flow rate 27 l/min, pressure 0.7 bar
- large color TFT display, multilingual interface
- central rotary knob (controller) simplifies operation
- Integrated programmer
- Integrated external Pt100 connection
- PID3 cascade temperature control
Technical data for DYNEO DD-1001F-BF
Dimensions and volumes
Dimensions (W × L × H) |
45 x 64 x 95 cm
|
Filling volume
|
48 ... 56 l
|
Weight
|
73.7 kg
|
Pump connections
|
M16x1 male
|
Barbed fittings inner diameter
|
8/12 mm
|
Temperature values
Working temperature range
|
-38 ... +100 °C |
Temperature stability
|
±0.01 °C
|
Setting the resolution of the temperature display
|
0.01 °C
|
Temperature display resolution
|
0.01 °C
|
Ambient temperature
|
+5 ... +40 °C
|
Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity
|
2 kW |
Cooling capacity
°C |
20 |
10 |
0 |
-10 |
-20 |
-30 |
kW
1
|
1 |
0.95 |
0.85 |
0.6 |
0.32 |
0.12 |
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
|
Pump capacity flow pressure
|
8 ... 27 l/min |
Pump capacity pressure
|
0.1 ... 0.7 bar |
Viscosity max.
|
50 cSt
|
Power consumption |
16 A
|
Bath
Bath tank
|
Stainless steel
|
Bath cover
|
integrated
|
Usable bath opening (W x L / D) |
35 x 41 / 30 cm
|
Cooling
Cooling of compressor
|
1-stage Air
|
Other
Classification
according to DIN12876-1
|
Classification III (FL)
|
Pump function
|
Pressure Pump
|
Pump type
|
Immersion Pump |
User Interface Language
|
Chinese / English / French / German / Italian / Japanese / Korean / Portuguese / Russian / Spanish
|
Electronics
Interfaces
|
Alarm output optional / REG/EPROG optional / RS232 optional / Standby-Input optional / USB
|
External pt100 sensor connection
|
integrated
|
Integrated programmer
|
8x60 steps
|
Temperature control
|
PID3
|
Absolute temperature calibration
|
3 Point Calibration
|
Temperature display
|
3.5" TFT Display
|
Temperature setting
|
Shaft Encoder
|
Electronic Timer
h:min
|
00:00 ... 99:59
|
Available voltage versions
9021709.04.D |
230V/50-60Hz (UK Plug Type BS1363A) (R449A) |
9021709.05.D |
230V/50-60Hz (CH Plug Type SEV 1011) (R449A) |
9021709.33.D |
230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R449A) |
9021709.33.chn.D |
230V/50-60Hz (CN Plug) (R449A) |
Included in delivery
Stainless steel insert basket for 20 x 0.5 liter bottles Plexiglass bath cover. |
Accessory for DYNEO DD-1001F-BF
Downloads for DYNEO DD-1001F-BF
We would also be happy to send you our printed catalogs and brochures by post.