PRESTO A40 Process system
Compact process systems down to -45 °C
JULABO's air-cooled PRESTO A40 process system combines high performance and a very compact design with all the advantages of the PRESTO series for a working temperature range from -40 °C to +250 °C.
The highly dynamic temperature control systems PRESTO are designed for high-precision temperature control for a wide range of applications such as reactor vessels or material stress tests. Moreover, by using efficient components, the process systems can compensate exothermic and endothermic reactions exceptionally fast. Permanent internal monitoring and self-lubricating pumps ensure a long life-time. In addition, numerous interfaces offer many remote control possibilities across networks or for integration into higher-level control systems.
Order number including voltage version | see refrigerant variants |
---|---|
Working temperature range | -40 ... +250 °C |
Temperature stability | ±0.01 ... ±0.05 °C |
Heating capacity | 2.7 kW |
Pump capacity flow pressure | 0 ... 40 l/min |
Pump capacity pressure | 0.1 ... 1.7 bar |
Total dimensions
(W × L × H) |
33 x 59 x 67 cm |
Product Features
- Heating capacity up to 2.7 kW
- Temperature stability ±0.01 °C ... ±0.05 °C
- Alarm output
- Built-in 5.7’’ industrial color touchscreen
- External Pt100 sensor connection
- Second external Pt100 sensor connection (accessory)
- Connections for USB, Ethernet, RS232, and Alarm output
- Analog connections, RS485, Profibus DP (accessory)
- Pump pressure up to 1.7 bar, max. flow rate 40 l/min
- removable ventilation grid
- RS232
- RS485 (Accessory)
- Profibus DP (Accessory)
- Cooling capacity up to 1.2 kW
Technical data for PRESTO A40
Total dimensions (W × L × H) |
33 x 59 x 67 cm |
---|---|
Filling volume expansion vessel | 4.8 l |
Internal usable expansion volume | 2.7 l |
Minimal process volume | 3.5 l |
Active heat exchanger volume | 1.7 l |
Weight | 79 kg |
Pump connections | M24x1.5 male |
Working temperature range | -40 ... +250 °C |
---|---|
Temperature stability | ±0.01 ... ±0.05 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5 ... +40 °C |
Heating capacity | 2.7 kW | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 0 ... 40 l/min | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity pressure | 0.1 ... 1.7 bar | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Viscosity max. | 50 cSt | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power consumption | 16 A |
Cooling of compressor | 1-stage Air |
---|
Sound pressure level | 55 dbA |
---|---|
Classification according to DIN12876-1 |
Classification III (FL) |
IP Code according to IEC 60529 |
IP 21 |
Pump type | Centrifugal Pump (Magnetically coupled) |
Interfaces | Alarm output / Ethernet / Modbus TCP/IP / Profibus optional / REG/EPROG optional / RS232 / RS485 optional / SD memory card / Standby-Input optional / USB |
---|---|
External pt100 sensor connection | integrated |
2nd external Pt100 sensor connection | accessory |
Integrated programmer | 8x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | 5.7" TFT Touchscreen |
Temperature setting | Touchscreen |
9420401.33 | 200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R507) |
---|---|
9420401.04 | 230V/50-60Hz (UK Plug Type BS1363A) (R449A) |
9420401.05 | 230V/50-60Hz (CH Plug Type SEV 1011) (R449A) |
9420401.14 | 208V/60Hz (Nema N6-20 Plug) (R449A) |
Accessory for PRESTO A40
Downloads for PRESTO A40
We would also be happy to send you our printed catalogs and brochures by post.
Request brochurePRESTO A40 Benefits
100 % Cooling capacity
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures
Intelligent temperature control.
Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.
Full control
‘Temperature Control Features’, for individual optimization, access to all important control parameters, additional settings for band limit, limits, co-speedfactor etc.
Control of the external application
External Pt100 sensor connection for precise measurement and control directly in the external application
Related Products
Products with similar properties