FP55-SL Ultra-Low Refrigerated / Heating Circulator

with filling port upgradeable with additional heating and pump capacity for external control only

Ultra-Low Refrigerated Circulators with SL circulator impress with their high heating, cooling and pump capacities for external temperature control applications.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
FP55-SL
Order number including voltage version see refrigerant variants
Working temperature range -55 ... +150 °C
Temperature stability ±0.05 °C
Heating capacity 3 kW
Pump capacity flow pressure 22 ... 26 l/min
Pump capacity pressure 0.4 ... 0.7 bar
Filling volume 27 l
Total dimensions
(W × L × H)
85 x 76 x 116 cm
Arrange callback

Product Features

  • VFD COMFORT DISPLAY
  • LCD DIALOG DISPLAY backlit for convenient interactive operation
  • Keypad for setpoints, warning/safety values and menu functions
  • ICC (Intelligent Cascade Control), self-optimizing temperature control
  • TCF Temperature Control Features to optimize the control behavior
  • ATC3 3-Point-Calibration
  • Pt100 External sensor connection for measurement and control
  • SMART PUMP, electronically adjustable pump stages
  • Unique early warning system for low liquid level
  • Adjustable high temperature cut-out, visible via display
  • RS232/RS485 interface for online communication
  • Integrated programmer for 6 x 60 program steps
  • Connections for solenoid valve and HSP booster pump
  • Proportional cooling control
  • Active Cooling Control

Technical data for FP55-SL

Dimensions and volumes
Total dimensions
(W × L × H)
85 x 76 x 116 cm
Filling volume 27 l
Weight 180 kg
Pump connections M16x1 male
Temperature values
Working temperature range -55 ... +150 °C
Temperature stability ±0.05 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5 ... +40 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 3 kW
Cooling capacity
Refrigerant variant
Order number including voltage version 9352755N150.07
Medium: Ethanol
°C 20 0 -20 -40 -50
kW 1 5.2 4.1 2.2 0.7 0.3
Refrigerant R452A
Global Warming Potential 2140
Filling weight 2000 g
Carbon dioxide equivalent 4.28 t
Refrigerant variant S1
Order number including voltage version 9352755N150.S1.07
Medium: Ethanol
°C 20 0 -20 -40 -50
kW 1 5.2 4 1.95 0.67 0.26
Refrigerant R449A
Global Warming Potential 1397
Filling weight 2000 g
Carbon dioxide equivalent 2.794 t

1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.

Pump capacity flow pressure 22 ... 26 l/min
Pump capacity pressure 0.4 ... 0.7 bar
Maximum suction 0.2 ... 0.4 bar
Viscosity max. 70 cSt
Power consumption 20 A
Bath
Bath cover integrated
Cooling
Cooling of compressor 1-stage Air
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Electronics
Interfaces Profibus optional
External pt100 sensor connection integrated
Integrated programmer 6x60 steps
Temperature control ICC
Absolute temperature calibration 3 Point Calibration
Temperature display VFD
Temperature setting Keypad
Available voltage versions
9352755N150.07 400V/3PNPE/50Hz (Plug 32A CEE) (R452A)
9352755N150.S1.07 400V/3PNPE/50Hz (Plug 32A CEE) (R449A)
9352755N150.16 208V/3PPE/60Hz (Without Plug) (R452A)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female).

Accessory for FP55-SL

Downloads for FP55-SL

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

FP55-SL Benefits

Connection of additional equipment

Stakei connections for solenoid valve, HSP booster pump and HST booster heater

Early warning system for high/low temperature limits

Maximum safety for applications, optical and audible alarm, convertible to automated cut-off function

Clever pump system

Reliable and consistent pump capacity, electronically adjustable pump stages

Control of the external application

External Pt100 sensor connection for precise measurement and control directly in the external application

Show all 17 benefits

JULABO customer survey

We appreciate if you take part and help us to further improve. The survey takes only 3 minutes and is anonymous. Thank you!

Compare products