Forte HT high temperature circulators
for working temperatures from +70 °C to +400 °C
High temperature circulators of the FORTE HT series are designed for temperature control in closed external systems. These compact units have a closed design that prevents the escape of oil vapors especially at high temperatures.
Product Features
- Integrated programmer for 6 x 60 program steps
- Strong pumping capacity 18 l/min - 1.2 bar max
- Automatic air-purge allows easy filling
- Backlit interactive 4-line LCD display
- Electronic level indication
- Self-optimizing ICC temperature controller
Product Overview
Forte HT high temperature circulators
2-zone technique for working temperatures up to 400 °C
![High temperature circulator HT30-M1 from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_7pjg13agth1njbo72gu13c2i6h/-S96-FJPG/9800031-ht30-m1-1.jpg)
JULABO high temperature circulators can be used for temperature applications up to +400 °C. The units provide powerful heating capacities for shortest heat-up times and rapid compensation of exothermic and endothermic reactions. The closed construction prevents oil fumes even at high temperatures. The units provide automatic heat-up and cracking protection to ensure long life-time of the bath fluid. The filling system automatically purges the fluid system of air. Units with model designation ‚C.U.‘ are equipped with a powerful cooling unit for tap water connection. This allows for temperature applications already at +20 °C and for rapid cooling. Typical applications: Reactors, autoclaves, distillation columns, miniplant installations, pilot plants and production facilities.
Model | Add to compare HT30-M1 |
Add to compare HT60-M3 |
Add to compare HT60-M2 |
---|---|---|---|
Working temperature range (°C) | +70 ... +400 | +70 ... +400 | +70 ... +400 |
Temperature stability (°C) | ±0.01 ... ±0.1 | ±0.01 ... ±0.1 | ±0.01 ... ±0.1 |
Heating capacity (kW) | 3 | 6 | 7 |
Pump capacity flow pressure (l/min) | 14 ... 18 | 14 ... 18 | 14 ... 18 |
Pump capacity pressure (bar) | 0.8 ... 1.2 | 0.8 ... 1.2 | 0.8 ... 1.2 |
Forte HT with cooling unit
2-zone technique for working temperatures up to 400 °C
![High temperature circulator with cooling unit HT30-M1-C.U. from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_1e0tl6dq994fla4r7l17tdff4v/-S96-FJPG/9800035-ht30-m1-c.u-1.jpg)
JULABO high-temperature circulators make temperature applications up to +400 °C possible. Models with the type suffix “C.U.” have a powerful cooling unit for connection of tap water. This makes temperature applications from +20 °C and quick cooling phases possible. Typical applications are reactors, autoclaves, distillation columns and mini-plant, technical or production facilities.
Model | Add to compare HT60-M3-C.U. |
Add to compare HT30-M1-C.U. |
Add to compare HT60-M2-C.U. |
---|---|---|---|
Working temperature range (°C) | +40 ... +400 | +40 ... +400 | +40 ... +400 |
Temperature stability (°C) | ±0.01 ... ±0.1 | ±0.01 ... ±0.1 | ±0.01 ... ±0.1 |
Heating capacity (kW) | 6 | 3 | 7 |
Pump capacity flow pressure (l/min) | 14 ... 18 | 14 ... 18 | 14 ... 18 |
Pump capacity pressure (bar) | 0.8 ... 1.2 | 0.8 ... 1.2 | 0.8 ... 1.2 |