FP51-SL Ultra-Low Refrigerated / Heating Circulator
low temperatures below -50 °C with bath opening for internal and external applications
The Ultra-Low Refrigerated Circulators of the HighTech Series with HL or SL circulator feature powerful pressure and suction pumps. The in-struments provide the entire variety of functions of the professional HighTech Series of circulators.
Performance data depends on the mains voltage in the country of use. Please select:
Order number including voltage version | see refrigerant variants | ||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -51 ... +200 °C | ||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature stability | ±0.05 °C | ||||||||||||||||||||||||||||||||||||||||||||||||||
Heating capacity | 3 kW | ||||||||||||||||||||||||||||||||||||||||||||||||||
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 22 ... 26 l/min | ||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity pressure | 0.4 ... 0.7 bar | ||||||||||||||||||||||||||||||||||||||||||||||||||
Usable bath opening (W x L / D) |
18 x 12 / 20 cm | ||||||||||||||||||||||||||||||||||||||||||||||||||
Filling volume | 7.5 ... 12 l | ||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions
(W × L × H) |
46 x 55 x 89 cm |
Product Features
- VFD COMFORT DISPLAY
- LCD DIALOG DISPLAY backlit for convenient interactive operation
- Keypad for setpoints, warning/safety values and menu functions
- ICC (Intelligent Cascade Control), self-optimizing temperature control
- TCF Temperature Control Features to optimize the control behavior
- ATC3 3-Point-Calibration
- Pt100 External sensor connection for measurement and control
- SMART PUMP, electronically adjustable pump stages
- Unique early warning system for low liquid level
- Adjustable high temperature cut-out, visible via display
- RS232/RS485 interface for online communication
- Integrated programmer for 6 x 60 program steps
- Connections for solenoid valve and HSP booster pump
- Proportional cooling control
- Active Cooling Control
Technical data for FP51-SL
Dimensions (W × L × H) |
46 x 55 x 89 cm |
---|---|
Filling volume | 7.5 ... 12 l |
Weight | 90 kg |
Pump connections | M16x1 male |
Working temperature range | -51 ... +200 °C |
---|---|
Temperature stability | ±0.05 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5 ... +40 °C |
Performance data depends on the mains voltage in the country of use. Please select:
Heating capacity | 3 kW | ||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 22 ... 26 l/min | ||||||||||||||||||||||||||||||||||||||||||||||||||
Pump capacity pressure | 0.4 ... 0.7 bar | ||||||||||||||||||||||||||||||||||||||||||||||||||
Maximum suction | 0.2 ... 0.4 bar | ||||||||||||||||||||||||||||||||||||||||||||||||||
Viscosity max. | 70 cSt | ||||||||||||||||||||||||||||||||||||||||||||||||||
Power consumption | 16 A |
Bath cover | integrated |
---|---|
Usable bath opening (W x L / D) |
18 x 12 / 20 cm |
Cooling of compressor | 1-stage Air |
---|
Sound pressure level | 63 dbA |
---|---|
Classification according to DIN12876-1 |
Classification III (FL) |
IP Code according to IEC 60529 |
IP 21 |
Interfaces | Profibus optional |
---|---|
External pt100 sensor connection | integrated |
Integrated programmer | 6x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 3 Point Calibration |
Temperature display | VFD |
Temperature setting | Keypad |
9352751.06 | 230V/3PPE/50Hz (Without Plug) (R507) |
---|---|
9352751.07 | 400V/3PNPE/50Hz (Plug 16A CEE) (R507) |
9352751.S1.07 | 400V/3PNPE/50Hz (Plug 16A CEE) (R449A) |
9352751.16 | 208V/3PPE/60Hz (Without Plug) (R507) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for FP51-SL
Downloads for FP51-SL
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureFP51-SL Benefits
![Safety level S3 unattended operation of temperature control units](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_mo1akcbiep1hrbe7o3sjhj334j/-S65-FJPG/s3.jpg)
For flammable bath fluid
Classification III (FL) according to DIN 12876-1
![Icon Absolute Temperature Calibration](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_hem750ar7l5fjbcp0mdv0n3a65/-S65-FJPG/atc3.jpg)
ATC3. Calibration.
‘Absolute Temperature Calibration’ for compensating a physically caused temperature difference, 3-point calibration.
![Icon Temperature Control Features](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_mpouftvdah76v14amp7ha2us60/-S65-FJPG/tcf.jpg)
Process. Under control.
Full regulation of the dynamics control, access to all important control parameters for individual process optimization.
![Active Cooling Control](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_rf0abv128p0k18694ea0a34334/-S65-FJPG/acc.jpg)
100 % Cooling capacity
‘Active Cooling Control’ for cooling available throughout the entire working temperature range, fast cool-down even at higher temperatures