DYNEO DD-1201F-BF Beer forcing test refrigerated / heating circulating bath new

to determine the ‘best before’ date of beer

The beer force test is a method used to determine the shelf life and stability of beer. This test is performed to analyze a beer's shelf life and tendency to microbiological or chemical change. The objective of this test is to quickly predict the beer's behavior over long storage periods. This is done by bottling beer samples and simulating artificial, accelerated aging by means of temperature cycles. This is repeated until an initial turbidity is detected by a photometer. The force test is particularly useful for breweries optimizing their product quality assurance process, helping them identify potential problems before their beer is released to the market.

DYNEO DD-1201F-BF has all the temperature profiles necessary to perform the force test, for both stabilized and untreated beer, already installed. If specific changes to the program settings are needed, the user can make these changes at any time and in a simplified manner.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
DD-1201F-BF
Working temperature range -40 ... +100 °C
Temperature stability ±0.01 °C
Usable bath opening
(W x L / D)
13.8 x 15.7 / 11.8 in.
Filling volume 48 ... 56 l
Dimensions
(W × L × H)
17.7 x 25.2 x 37.4 in.
Arrange callback

Product Features

  • Automatic cycles of temperature ramps simulate aging
  • Pre-programmed temperature profiles for forcing test
  • Program modification possible at any time
  • Large bath opening with insert for 20 bottles, 0.5 liters each (Racks for other bottle sizes on request)
  • Removable Plexiglass® cover
  • RS232 interface for online communication
  • powerful and infinitely adjustable pressure pump
  • Flow rate 27 l/min, pressure 0.7 bar
  • large color TFT display, multilingual interface
  • central rotary knob (controller) simplifies operation
  • Integrated programmer
  • Integrated external Pt100 connection
  • PID3 cascade temperature control

Technical data for DYNEO DD-1201F-BF

Dimensions and volumes
Dimensions
(W × L × H)
17.7 x 25.2 x 37.4 in.
Filling volume 48 ... 56 l
Weight 149.9 lbs
Pump connections M16x1 male
Barbed fittings inner diameter 8/12 mm
Temperature values
Working temperature range -40 ... +100 °C
Temperature stability ±0.01 °C
Setting the resolution of the temperature display 0.01 °C
Temperature display resolution 0.01 °C
Ambient temperature +5 ... +40 °C

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Bath
Bath tank Stainless steel
Bath cover integrated
Usable bath opening
(W x L / D)
13.8 x 15.7 / 11.8 in.
Cooling
Cooling of compressor 1-stage Air
Other
Classification
according to DIN12876-1
Classification III (FL)
IP Code
according to IEC 60529
IP 21
Pump function Pressure Pump
Pump type Immersion Pump
User Interface Language Chinese / English / French / German / Italian / Japanese / Korean / Portuguese / Russian / Spanish
Electronics
Interfaces Alarm output optional / REG/EPROG optional / RS232 optional / Standby-Input optional / USB
External pt100 sensor connection integrated
Integrated programmer 8x60 steps
Temperature control PID3
Absolute temperature calibration 3 Point Calibration
Temperature display 3.5" TFT Display
Temperature setting Shaft Encoder
Electronic Timer
h:min
00:00 ... 99:59
Available voltage versions
9021719.N1.04.D 200-230V/50-60Hz (UK Plug Type BS1363A) (R1270)
9021719.N1.05.D 200-230V/50-60Hz (CH Plug Type SEV 1011) (R1270)
9021719.N1.33.D 200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R1270)
9021719.N1.33.chn.D 200-230V/50-60Hz (CN Plug) (R1270)
9021719.N1.22.D 100-115V/50-60Hz (Nema N6-20 Plug) (R1270)
Included in delivery
Stainless steel insert basket for 20 x 0.5 liter bottles Plexiglass bath cover.

Accessory for DYNEO DD-1201F-BF

Downloads for DYNEO DD-1201F-BF

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

DYNEO DD-1201F-BF Benefits

Handle with ease.

Makes day-to-day work easy. Comfortably move your CORIO around by using the ergonomic handles (front and rear).

Highly precise

PID Temperature control with drift compensation and adjustable control parameters, temperature stability ±0.01...±0.02 °C

Wide range.

Refrigerated and heating circulator in various combinations, circulator in various sizes. Maximum flexibility through large selection of accessories.

Brilliance. In color.

Large color display with vivid luminance is easy to read, even from a large distance.

Show all 20 benefits