MAGIO laboratory circulators
With the new MAGIO series, JULABO is expanding its product portfolio of high-end bridge mounted circulators, refrigerated and heating circulators – naturally all in the usual premium quality. The circulators operate in a working temperature range from -50 °C to +300 °C and with a heating capacity of up to 3 kW. Excellent heating/cooling performance guarantees very short heat-up and cool-down times.
Powerful
The MAGIO devices offer the most powerful pump in their class. They are suitable for demanding external temperature control tasks and can be individually adapted to your applications.
Modern touch display
The high-resolution, modern TFT touch display shows all important information at a glance. All display functions are easy to operate with a fingertip.
Simple data exchange
Modern interfaces make easy remote control and practical data management possible on all MAGIO devices, as well as allowing integration into process structures.
Energy efficient and climate friendly
The new MAGIO cooling machines work with natural refrigerant. In addition to reducing operating costs, the focus on energy efficiency also helps to protect the environment.
MAGIO Circulators - an overview of the categories
MAGIO MS refrigerated / heating circulator
with extremely powerful pressure/suction pump and intuitive touch display
![Refrigerated / heating circulator MAGIO MS-1200F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_0snhs0aj7p3sd474thundnpb6h/-S96-FJPG/9032717-magio-ms-1200f-1.jpg)
As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. The devices offer extra strong pressure and suction pumps, thus fulfilling the highest demands for temperature control of external applications. Whether in basic research, material testing or technical systems – the MAGIO refrigerated circulators offer high-tech solutions for high customer requirements.
Model | Add to compare MAGIO MS-310F |
Add to compare MAGIO MS-449F |
Add to compare MAGIO MS-450F |
Add to compare MAGIO MS-600F |
---|---|---|---|---|
Working temperature range (°C) | -30 ... +200 | -30 ... +200 | -30 ... +200 | -35 ... +200 |
Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
Cooling capacity (kW) | 0.33 | 0.46 | 0.46 | 0.6 |
Heating capacity (kW) | 1 | 1 | 1 | 1 |
Pump capacity flow pressure (l/min) | 16 ... 31 | 16 ... 31 | 16 ... 31 | 16 ... 31 |
Pump capacity pressure (psi) | 3.5 ... 13.3 | 3.5 ... 13.3 | 3.5 ... 13.3 | 3.5 ... 13.3 |
Model | Add to compare MAGIO MS-601F |
Add to compare MAGIO MS-800F |
Add to compare MAGIO MS-1000F |
Add to compare MAGIO MS-1000FW |
---|---|---|---|---|
Working temperature range (°C) | -35 ... +200 | -40 ... +200 | -50 ... +200 | -50 ... +200 |
Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
Cooling capacity (kW) | 0.6 | 0.86 | 1 | 1 |
Heating capacity (kW) | 1 | 0.8 | 1 | 1 |
Pump capacity flow pressure (l/min) | 16 ... 31 | 16 ... 31 | 16 ... 31 | 16 ... 31 |
Pump capacity pressure (psi) | 3.5 ... 13.3 | 3.5 ... 13.3 | 3.5 ... 13.3 | 3.5 ... 13.3 |
Model | Add to compare MAGIO MS-1200F |
Add to compare MAGIO MS-1200FW |
---|---|---|
Working temperature range (°C) | -50 ... +200 | -50 ... +200 |
Temperature stability (°C) | ±0.01 | ±0.01 |
Cooling capacity (kW) | 1.26 | 1.2 |
Heating capacity (kW) | 0.8 | 0.8 |
Pump capacity flow pressure (l/min) | 16 ... 31 | 16 ... 31 |
Pump capacity pressure (psi) | 3.5 ... 13.3 | 3.5 ... 13.3 |
MAGIO MS and MX bridge mounted circulators
with extremely powerful pump and intuitive touch display
![Bridge mounted circulator MAGIO MS-Z from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_55cmagacal583a2s0nfc16320u/-S96-FJPG/9032201-magio-ms-z-1.jpg)
MAGIO bridge mounted circulators combine high temperature control performance with maximum flexibility. The adjustable bridge means that the circulators can be used with bath tanks up to a filling volume of 100 liters.
Model | Add to compare MAGIO MS-Z |
Add to compare MAGIO MX-Z |
---|---|---|
Working temperature range (°C) | +20 ... +300 | +20 ... +300 |
Temperature stability (°C) | ±0.01 | ±0.01 |
Heating capacity (kW) | 1 | 2.3 |
Pump capacity flow pressure (l/min) | 16 ... 31 | 16 ... 31 |
Pump capacity pressure (psi) | 3.5 ... 13.3 | 3.5 ... 13.3 |
MAGIO MS / MX heating circulators
with extremely powerful pumps, intuitive touchscreen displays
![Heating circulator MAGIO MS-BC4 from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_3s010op7k90qne99kt9p177a56/-S96-FJPG/9032504-magio-ms-bc4-1.jpg)
Like all circulators in the MAGIO range, the heating circulators are characterised by premium quality and high performance combined with intuitive usability. The devices offer extra powerful pressure and suction pumps to meet the most challenging demands for temperature control of external applications. Samples can also be temperature controlled in the internal bath of the high-quality, insulated and closed bath tank.
Model | Add to compare MAGIO MS-BC4 |
Add to compare MAGIO MX-BC6 |
Add to compare MAGIO MX-BC12 |
Add to compare MAGIO MX-BC26 |
---|---|---|---|---|
Working temperature range (°C) | +20 ... +300 | +20 ... +300 | +20 ... +300 | +20 ... +300 |
Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
Heating capacity (kW) | 1 | 2.3 | 2.3 | 2.3 |
Pump capacity flow pressure (l/min) | 16 ... 31 | 16 ... 31 | 16 ... 31 | 16 ... 31 |
Pump capacity pressure (psi) | 3.5 ... 13.3 | 3.5 ... 13.3 | 3.5 ... 13.3 | 3.5 ... 13.3 |