FL Recirculating coolers

Chill Environmentally Friendly and Economical

The FL series offers a new generation of chillers for routine cooling applications within the laboratory and industry. The temperature stability of the PID control is ±0.5°C.

All units can easily be cleaned and are provided with a splash water proof keypad with LED temperature indication. On the front of the units there is an RS232 interface as well as an alarm shutdown. The filling port is easily accessible placed on the top under a lift-up cover. Another hinged tray serves as a file for the operating manual or other documents concerning the installation. The removable venting grid allows an easy cleaning of the condenser, the drain tap is easily accessible behind the grid. All models include an easily visible level indication. Another advantage is the venting slots are on the front and rear and therefore the units can be placed directly one beside the other (space saving).

Product Features

  • Splash-proof keypad
  • Large, bright LED display
  • Reliable Microprocessor PID temperature control
  • Powerful immersion pumps, suitable for continuous operation
  • Easy filling and Drain tap easily accessible
  • Low liquid level protection with optical and audible alarm signal
  • Front drain
  • No side vents, instruments can be placed right next to other equipment
  • RS232 interface for PC connection
  • Easy filling from the top with hinged protective lid
  • Ergonomic design and easy operation
  • Pressure Indicator

Product Overview

FL Recirculating cooler up to 1.7 KW cooling capacity

compact models with up to 1.7 kW of cooling capacity for installation below a lab bench

The compact FL models are suited for a wide variety of cooling tasks. Installation under a lab bench saves valuable space. 2 variants: Air-cooled (FL) and water-cooled (FLW).

Model
Add to compare
FL300
Add to compare
FL601
Add to compare
FL1201
Add to compare
FL1203
Working temperature range (°C) -20 ... +40 -20 ... +40 -20 ... +40 -20 ... +40
Temperature stability (°C) ±0.5 ±0.5 ±0.5 ±0.5
Cooling capacity (kW) 0.3 0.6 1.2
Pump capacity flow pressure (l/min) 15 23 23
Pump capacity pressure (psi) 5.1 14.5 14.5
Model
Add to compare
FL1701
Add to compare
FL1703
Add to compare
FLW1701
Add to compare
FLW1703
Working temperature range (°C) -20 ... +40 -20 ... +40 -20 ... +40 -20 ... +40
Temperature stability (°C) ±0.5 ±0.5 ±0.5 ±0.5
Cooling capacity (kW) 1.7 1.7
Pump capacity flow pressure (l/min) 23 23
Pump capacity pressure (psi) 14.5 14.5

FL Recirculating cooler with up to 4.3 kW of cooling capacity

The FL models shown here have higher cooling capacity, powerful circulating pumps, and internal bath volumes of up to 30 liters. 2 variants: Air-cooled (FL) and water-cooled (FLW).

Model
Add to compare
FL2503
Add to compare
FL2506
Add to compare
FLW2506
Add to compare
FLW2503
Working temperature range (°C) -20 ... +40 -15 ... +40 -15 ... +40 -20 ... +40
Temperature stability (°C) ±0.5 ±0.5 ±0.5 ±0.5
Cooling capacity (kW) 2.5 2.5 2.5 2.7
Pump capacity flow pressure (l/min) 40 60 60 40
Pump capacity pressure (psi) 7.3 ... 43.5 7.3 ... 87 7.3 ... 87 7.3 ... 43.5
Model
Add to compare
FL4003
Add to compare
FLW4003
Add to compare
FL4006
Add to compare
FLW4006
Working temperature range (°C) -20 ... +40 -20 ... +40 -20 ... +40 -15 ... +40
Temperature stability (°C) ±0.5 ±0.5 ±0.5 ±0.5
Cooling capacity (kW) 4 4.3 4 4
Pump capacity flow pressure (l/min) 40 40 60 60
Pump capacity pressure (psi) 7.3 ... 43.5 7.3 ... 43.5 7.3 ... 87 7.3 ... 87

FL Recirculating cooler with up to 20 kW of cooling capacity

Models with particularly high power reserves

The powerful FL models are suitable for a wide range of cooling tasks in industrial environments, such as removal of large process heat. 2 variants: Air-cooled (FL) and water-cooled (FLW).

Model
Add to compare
FL7006
Add to compare
FLW7006
Add to compare
FL11006
Add to compare
FLW11006
Working temperature range (°C) -20 ... +40 -20 ... +40 -20 ... +40 -20 ... +40
Temperature stability (°C) ±0.5 ±0.5 ±0.5 ±0.5
Cooling capacity (kW) 7 7.4 10.3 11.5
Pump capacity flow pressure (l/min) 60 60 60 60
Pump capacity pressure (psi) 7.3 ... 87 7.3 ... 87 7.3 ... 87 7.3 ... 87
Model
Add to compare
FL20006
Add to compare
FLW20006
Working temperature range (°C) -25 ... +40 -25 ... +40
Temperature stability (°C) ±0.5 ±0.5
Cooling capacity (kW) 20 23.5
Pump capacity flow pressure (l/min) 80 80
Pump capacity pressure (psi) 11.6 ... 87 11.6 ... 87
Compare products