MAGIO MS-449F Refrigerated / heating circulator new
with extremely powerful pressure/suction pump and intuitive touch display
As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. The devices offer extra strong pressure and suction pumps, thus fulfilling the highest demands for temperature control of external applications. Whether in basic research, material testing or technical systems – the MAGIO refrigerated circulators offer high-tech solutions for high customer requirements.
The MAGIO MS-449F refrigerated circulator has an exceptionally large bath volume. This makes the unit ideal for precisely tempering larger or a variety of different samples in the bath.
Plenty of room for samples in the bath
The cooling machine 449F features an extraordinarily large bath volume. The unit is therefore perfect for precise temperature control of larger or a variety of samples in the bath. The height-adjustable shelf, which is available as an accessory, further enhances the flexibility of application.
Performance data depends on the mains voltage in the country of use. Please select:
Order number including voltage version | 9032716.N1.02 | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | -30 ... +200 °C | ||||||||||||||||||||||||||||||||||||
Temperature stability | ±0.01 °C | ||||||||||||||||||||||||||||||||||||
Heating capacity | 1 kW | ||||||||||||||||||||||||||||||||||||
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 16 ... 31 l/min | ||||||||||||||||||||||||||||||||||||
Pump capacity pressure | 3.5 ... 13.3 psi | ||||||||||||||||||||||||||||||||||||
Usable bath opening (W x L / D) |
11 x 13.8 / 7.9 in. | ||||||||||||||||||||||||||||||||||||
Filling volume | 18 ... 26 l | ||||||||||||||||||||||||||||||||||||
Dimensions
(W × L × H) |
14.6 x 23.2 x 27.2 in. |
Product Features
- Ideal for demanding external applications
- Simple control of complex applications
- Continuously adjustable, extremely powerful pressure / suction pump
- Flow rate 16 ... 31 l / min, pressure 0.24 ... 0.92 bar, suction 0.03 ... 0.4 bar
- Large, high-resolution TFT touch display with multilingual user interface
- Parts being in contact with the medium made of stainless steel
- Integrated programmer
- Integrated external Pt100 connection
- USB connection
- RS232 interface for online communication
- Ethernet
- analog interfaces (accessory)
- Class III (FL) according to DIN 12876-1
- Connections for solenoid valve
- Integrated pump connection M16×1
Technical data for MAGIO MS-449F
Dimensions (W × L × H) |
14.6 x 23.2 x 27.2 in. |
---|---|
Filling volume | 18 ... 26 l |
Weight | 92.6 lbs |
Pump connections | M16x1 male |
Working temperature range | -30 ... +200 °C |
---|---|
Temperature stability | ±0.01 °C |
Setting the resolution of the temperature display | 0.01 °C |
Temperature display resolution | 0.01 °C |
Ambient temperature | +5 ... +40 °C |
Performance data depends on the mains voltage in the country of use. Please select:
Heating capacity | 1 kW | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
|||||||||||||||||||||||||||||||||||||
Pump capacity flow pressure | 16 ... 31 l/min | ||||||||||||||||||||||||||||||||||||
Pump capacity pressure | 3.5 ... 13.3 psi | ||||||||||||||||||||||||||||||||||||
Maximum suction | -0.4 ... -5.8 psi | ||||||||||||||||||||||||||||||||||||
Viscosity max. | 70 cSt | ||||||||||||||||||||||||||||||||||||
Power consumption | 12 A |
Bath tank | Stainless steel |
---|---|
Bath cover | integrated |
Usable bath opening (W x L / D) |
11 x 13.8 / 7.9 in. |
Cooling of compressor | 1-stage Air |
---|
Classification according to DIN12876-1 |
Classification III (FL) |
---|---|
IP Code according to IEC 60529 |
IP 20 |
Pump function | Pressure Suction Pump |
Pump type | Immersion Pump |
User Interface Language | Chinese / Czech / Dutch / English / French / German / Italian / Japanese / Korean / Polish / Portuguese / Russian / Spanish / Turkish |
Interfaces | Ethernet / Modbus / RS232 / RS485 / Stakei / USB |
---|---|
External pt100 sensor connection | integrated |
Integrated programmer | 8x60 steps |
Temperature control | ICC |
Absolute temperature calibration | 10 Point Calibration |
Temperature display | 7" TFT Touchscreen |
Temperature setting | Touchscreen |
Electronic Timer h:min |
00:00 ... 99:59 |
9032716.N1.01 | 100V/50-60Hz (Nema N5-15 Plug) (R290) |
---|---|
9032716.N1.02 | 115V/60Hz (Nema N5-15 Plug) (R290) |
9032716.N1.33 | 200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R290) |
9032716.N1.33.chn | 200-230V/50-60Hz (CN Plug) (R290) |
9032716.N1.04 | 200-230V/50-60Hz (UK Plug Type BS1363A) (R290) |
9032716.N1.05 | 200-230V/50-60Hz (CH Plug Type SEV 1011) (R290) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for MAGIO MS-449F
Downloads for MAGIO MS-449F
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureMAGIO MS-449F Benefits
![Icon ICC Intelligent Cascade Control - Automatic and self-optimizing adjustment of control parameters](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_cav7i4fj152rd57c8h7r5v961n/-S65-FJPG/icc-282-29.jpg)
Intelligent temperature control.
Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.
![Icon : Many interfaces for temperature control units](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_o499p3jjit043fpkqm39qu277d/-S65-FJPG/viele-schnittstellen.jpg)
Many interfaces.
Straight-forward remote control, data management, and integration into process structures. USB, Ethernet, RS232, SD card, and alarm off are permanently integrated. Further interfaces available as accessories.
![Icon: Touch display for the operation of temperature control units](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_lesp5mr9nh68ffpqre55cthg6u/-S65-FJPG/touch-display.jpg)
Touch display. Perfect operation.
With the touch display, the user always has an overview of all values and functions. The intuitive and multilingual menu structure enables perfect control.
![Icon: Maximum safety through unit cut-off of the circulator in the event of overtemperature or low liquid level.](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_i273cr2br53jvfcqr08m3cup1p/-S65-FJPG/fr-c3-bchwarnsystem.jpg)
Maximum safety.
Classification III according to DIN12876-1 enables safe operation, even with flammable fluids. Automatic switch-off in the event of high temperature or low liquid level.
Related Products
Products with similar properties
![Refrigerated / heating circulator CORIO CD-300F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_2pnt471db907nfsotrsslci90r/-S96-FJPG/9012703-corio-cd-300f-1.jpg)
![Refrigerated / heating circulator DYNEO DD-300F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_6mbrel38hd0up2p9rjk5d12p30/-S96-FJPG/9021703-dyneo-dd-300f-1.jpg)
![Refrigerated / heating circulator CORIO CP-201F from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_bvl5kqn3tl6rp2r1t05648m15j/-S96-FJPG/9013702-corio-cp-201f-1.jpg)