F1000 Compact Recirculating Cooler
Compact models for simple cooling tasks
The compact recirculating coolers in the F Series are economic models for routine applications in laboratories. The instruments cool in a temperature range of -10 or 0 °C to +40 °C and achieve a stability of ±0.5°C. The space saving design and lack of side vents allow flexible positioning even in small laboratories. Their high efficiency mean that the coolers in the F Series are an economic and environmentally friendly alternative to cooling with tap water. Low acquisition costs mean that they pay for themselves within a very short time.
Performance data depends on the mains voltage in the country of use. Please select:
Order number including voltage version | 9620100.02 | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Working temperature range | 0 ... +40 °C | |||||||||||||||||||
Temperature stability | ±0.5 °C | |||||||||||||||||||
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||
Pump capacity flow pressure | 23 l/min | |||||||||||||||||||
Pump capacity pressure | 14.5 psi | |||||||||||||||||||
Filling volume | 7 ... 9.5 l | |||||||||||||||||||
Dimensions
(W × L × H) |
14.8 x 19.3 x 25.2 in. |
Product Features
- Environmentally friendly operation with low energy consumption
- No side vents, instruments can be placed right next to other equipment
- All wetted parts made of stainless steel or high grade plastic (except FC-T models)
- Large, bright LED display
- Compact design
- Splash-proof keypad
- Easy filling and Drain tap easily accessible
Technical data for F1000
Dimensions (W × L × H) |
14.8 x 19.3 x 25.2 in. |
---|---|
Filling volume | 7 ... 9.5 l |
Weight | 99.2 lbs |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | 0 ... +40 °C |
---|---|
Temperature stability | ±0.5 °C |
Setting the resolution of the temperature display | 0.1 °C |
Temperature display resolution | 0.1 °C |
Ambient temperature | +5 ... +40 °C |
Return flow temperature max. | +80 °C |
Performance data depends on the mains voltage in the country of use. Please select:
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||
Pump capacity flow pressure | 23 l/min | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pump capacity pressure | 14.5 psi | |||||||||||||||||||
Power consumption | 9 A |
Bath tank | Stainless steel |
---|
Cooling of compressor | 1-stage Air |
---|
Sound pressure level | 62 dbA |
---|---|
Classification according to DIN12876-1 |
Classification I (NFL) |
IP Code according to IEC 60529 |
IP 20 |
Pump type | Centrifugal Pump |
Temperature control | PID1 |
---|---|
Temperature display | LED |
Temperature setting | Keypad |
9620100.03 | 230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a) |
---|---|
9620100.13 | 230V/60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R134a) |
9620100.02 | 115V/60Hz (Nema N5-15 Plug) (R134a) |
9620100.05 | 230V/50Hz (CH Plug Type SEV 1011) (R134a) |
9620100.04 | 230V/50Hz (UK Plug Type BS1363A) (R134a) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for F1000
Downloads for F1000
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureF1000 Benefits
![Quality control](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_hevpr7dgr57jnafu373htsrb7e/-S65-FJPG/100-25-proofed.jpg)
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
![Environmentally friendly design for temperature control units](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_ps5rbagui16lf9opehta6id43r/-S65-FJPG/green-technology.jpg)
Green technology.
Development consistently applied environmentally friendly materials and technologies.
![Logo Made in Germany](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_faesup1da50v9aao0q9jbvr00g/-S65-FJPG/made-in-germany.jpg)
JULABO. Quality.
Highest standards of quality for a long product life.
![Quick guide for JULABO temperature control units](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_aoao523ptt7pjb16gkdbhpsq35/-S65-FJPG/quickstart.jpg)
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.
Related Products
Products with similar properties
![Compact recirculating cooler F500 from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_jb4p2cu6sd19bets3ehjap1v1a/-S96-FJPG/9620050-f500-1.jpg)
![Recirculating Coolers for installation below a lab bench FL1201 from JULABO view 1](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_9a1qrkesu520n99767ntnhea5v/-S96-FJPG/9661012-fl1201-1.jpg)