CORIO C-B13 Open heating bath circulator with stainless steel bath tank

Laboratory circulators for internal temperature application at working temperatures from +20 to +100°C

The open heating bath circulators of the new CORIO series feature high-quality bath tanks made of stainless steel.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
C-B13
Order number including voltage version 9011413.22
Working temperature range 1 +20 ... +100 °C
Temperature stability ±0.03 °C
Heating capacity 1 kW
Usable bath opening
(W x L / D)
11.8 x 7.1 / 5.9 in.
Filling volume 9 ... 13 l
Total dimensions
(W × L × H)
15 x 15.7 x 16.5 in.

1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.

Arrange callback

Product Features

  • Bright, white, easy to read display
  • Very quiet
  • High-quality bath tanks made of stainless steel
  • for internal applications
  • Easy operation
  • Integrated drain screw (except B5)
  • Integrated drain screw

Technical data for CORIO C-B13

Dimensions and volumes
Total dimensions
(W × L × H)
15 x 15.7 x 16.5 in.
Filling volume 9 ... 13 l
Weight 18.1 lbs
Temperature values
Working temperature range 1 +20 ... +100 °C
Temperature stability ±0.03 °C
Setting the resolution of the temperature display 0.1 °C
Temperature display resolution 0.01 ... 0.1 °C
Ambient temperature +5 ... +40 °C

1 For applications near or below ambient temperature: use a cooling coil or JULABO immersion cooler.

Performance data depends on the mains voltage in the country of use. Please select:

Country of use | Mains voltage | Plug | JULABO voltage version code
Performance values
Heating capacity 1 kW
Viscosity max. 1 cSt
Circulation capacity flow rate 6 l/min
Circulation capacity pressure 1.5 psi
Power consumption 10 A
Bath
Bath tank Stainless steel
Usable bath opening
(W x L / D)
11.8 x 7.1 / 5.9 in.
Cooling
Cooling coil accessory
Other
Classification
according to DIN12876-1
Classification I (NFL)
IP Code
according to IEC 60529
IP 21
Pump type Immersion Pump
Electronics
Temperature control PID1
Absolute temperature calibration 1 Point Calibration
Temperature display LED
Temperature setting Keypad
Available voltage versions
9011413.22 100-115V/50-60Hz (Nema N5-15 Plug)
9011413.33.chn 230V/50-60Hz (CN Plug)
9011413.33 230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F)
9011413.04 230V/50-60Hz (UK Plug Type BS1363A)
9011413.05 230V/50-60Hz (CH Plug Type SEV 1011)

Accessory for CORIO C-B13

Downloads for CORIO C-B13

We would also be happy to send you our printed catalogs and brochures by post.

Request brochure

CORIO C-B13 Benefits

Brilliant.

Very bright display makes it easy to read even from a distance.

Switch on. And off you go.

Intelligent operating concept. Ready for operation with just a few quick and easy steps.

Timer. Integrated.

CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes.

Everything at the front.

All operating controls and safety functions are accessed easily and comfortably from the front.

Show all 16 benefits