Heating immersion circulators

with attachment clamp for any bath tank up to 50 liters filling volume

JULABO immersion circulators for controlling temperature in any bath tank up to 50 liters. These units are equipped with a bath attachment clamp for wall thicknesses up to 26 mm. Alternatively, the circulator may be fastened to a laboratory stand. The clamp makes it easy to install the circulator onto an existing bath tank.

Parts that are immersed in bath liquid are constructed of high quality stainless steel or synthetic material. Common applications include controlling the temperature of samples, temperature testing of food or luxury articles, materials testing, and evaluation, adjustment, and calibration or thermometers and thermal switches

Product Features

  • High heating capacities
  • Very quiet
  • Models for internal applications

Product Overview

CORIO C heating immersion circulators

The new generation of laboratory circulators

The CORIO C immersion circulator is the basic model of the CORIO circulator portfolio. The bath attachment clamp is included in delivery and facilitates mounting of the circulator on any bath tank up to 30 liters.

Model
Add to compare
CORIO C
Working temperature range (°C) +20 ... +100
Temperature stability (°C) ±0.03
Heating capacity (kW) 2
Circulation capacity flow rate (l/min) 6
Circulation capacity pressure (bar) 0.1

CORIO CD heating immersion circulators

Laboratory circulators for internal and external temperature applications until +150°C

CORIO CD heating immersion circulators can control the temperature of external applications thanks to their integrated pressure pump in conjunction with an optional pump set. The switch-over between internal and external temperature control is conveniently carried out on the front of the Unit. The bath attachment clamp supplied facilitates installation on any bath tanks up to a bath volume of 50 liters. All units offer a heating capacity of 2 kW at 230V.

Model
Add to compare
CORIO CD
Working temperature range (°C) +20 ... +150
Temperature stability (°C) ±0.03
Heating capacity (kW) 2
Pump capacity flow pressure (l/min) 15
Pump capacity pressure (bar) 0.35

CORIO CP heating immersion circulators

Laboratory circulators with extended pump capacity until +200 °C

With their infinitely adjustable pressure pump, the CORIO CP heating immersion circulators achieve a flow rate of until 27 l/min. CORIO CP heating immersion circulators are suitable for a wide range of routine tasks with different pressure requirements. The supplied bath attachment clamp facilitates installation on any bath tank until a bath volume of 50 liters is reached. All units offer a heating capacity of 2 kW at 230V.

Model
Add to compare
CORIO CP
Working temperature range (°C) +20 ... +200
Temperature stability (°C) ±0.02
Heating capacity (kW) 2
Pump capacity flow pressure (l/min) 8 ... 27
Pump capacity pressure (bar) 0.1 ... 0.7

DYNEO DD heating immersion circulators

Flexible laboratory circulators with a new operating concept

DYNEO DD heating circulators for internal and external applications are equipped with closed bath tanks. The tanks are well insulated and include a coil for counter-cooling. An integrated drain tap makes emptying the tank safe and clean. The multilingual 3.5-inch color display and unique rotary knob provide for straightforward and intuitive operation.

Model
Add to compare
DYNEO DD
Working temperature range (°C) +20 ... +200
Temperature stability (°C) ±0.01
Heating capacity (kW) 2
Pump capacity flow pressure (l/min) 8 ... 27
Pump capacity pressure (bar) 0.1 ... 0.7
Compare products