MAGIO MX-2500F Refrigerated / heating circulator new
Our most powerful laboratory circulators with the highest cooling and heating capacity
As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. These devices provide extra powerful pressure and suction pumps and have an incredibly high heating output of 3 kW, enabling even more dynamic temperature control for external applications.
With a working temperature range of -50 ... +200 °C, the Refrigerated / heating circulator MAGIO MX-2500F delivers an outstanding cooling capacity of 2.57 kW at 20 °C despite its compact design.
This cooling machine works with natural, environmentally-friendly refrigerant and was developed with a focus on energy efficiency. This means significant savings up to 70% on the operating costs for numerous applications, which also means rapid amortization of the procurement cost. At the same time, the lower energy consumption positively contributes to climate protection.
MAGIO MX-2500F Benefits
![Icon ICC Intelligent Cascade Control - Automatic and self-optimizing adjustment of control parameters](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_cav7i4fj152rd57c8h7r5v961n/-S65-FJPG/icc-282-29.jpg)
Intelligent temperature control.
Intelligent cascade control - automatic and self-optimizing adaptation of the PID control parameters with external stability of +/- 0.05 °C.
![Icon : Many interfaces for temperature control units](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_o499p3jjit043fpkqm39qu277d/-S65-FJPG/viele-schnittstellen.jpg)
Many interfaces.
Straight-forward remote control, data management, and integration into process structures. USB, Ethernet, RS232, SD card, and alarm off are permanently integrated. Further interfaces available as accessories.
![Icon: Touch display for the operation of temperature control units](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_lesp5mr9nh68ffpqre55cthg6u/-S65-FJPG/touch-display.jpg)
Touch display. Perfect operation.
With the touch display, the user always has an overview of all values and functions. The intuitive and multilingual menu structure enables perfect control.
![Icon: Maximum safety through unit cut-off of the circulator in the event of overtemperature or low liquid level.](https://dbyt75tph3sip.cloudfront.net/image/512030579289/image_i273cr2br53jvfcqr08m3cup1p/-S65-FJPG/fr-c3-bchwarnsystem.jpg)
Maximum safety.
Classification III according to DIN12876-1 enables safe operation, even with flammable fluids. Automatic switch-off in the event of high temperature or low liquid level.