CORIO CP-800F Refrigerated / heating circulator new
with an enhanced pump performance and a temperature range up to +200 °C
Refrigerated circulators from the CORIO CP range are suitable for applications with a temperature range up to +200°C. The enhanced pump performance ensures they are suitable for easy temperature control tasks in combination with external applications.
With a working temperature range of -40 ... +200 °C, the Refrigerated / heating circulator CORIO CP-800F delivers an outstanding cooling capacity of 0.84 kW at 20 °C despite its compact design.
This cooling machine works with natural, environmentally-friendly refrigerant and was developed with a focus on energy efficiency. This means significant savings on the operating costs for numerous applications, which also means rapid amortization of the procurement cost. At the same time, the lower energy consumption positively contributes to climate protection.
Overview
Technical data
Accessory & Services
Downloads
Performance data depends on the mains voltage in the country of use. Please select:
Country of use | Mains voltage | Plug | JULABO voltage version code
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids.
Pump capacity flow pressure
8 ... 27 l/min
Pump capacity pressure
0.1 ... 0.7 bar
Viscosity max.
50 cSt
Power consumption
11 A
Bath
Bath tank
Stainless steel
Bath cover
integrated
Usable bath opening (W x L / D)
18 x 13 / 15 cm
Cooling
Cooling of compressor
1-stage Air
Other
Classification according to DIN12876-1
Classification III (FL)
IP Code according to IEC 60529
IP 21
Pump function
Pressure Pump
Pump type
Immersion Pump
Electronics
Interfaces
RS232 / USB
Temperature control
PID1
Absolute temperature calibration
3 Point Calibration
Temperature display
LED
Temperature setting
Keypad
Electronic Timer h:min
0 ... 999
Available voltage versions
9013715.N1.22
100-115V/50-60Hz (Nema N5-20 Plug) (R1270)
9013715.N1.04
200-230V/50-60Hz (UK Plug Type BS1363A) (R1270)
9013715.N1.05
200-230V/50-60Hz (CH Plug Type SEV 1011) (R1270)
9013715.N1.33
200-230V/50-60Hz (Schuko Plug - CEE 7/4 Plug Type F) (R1270)
9013715.N1.33.chn
200-230V/50-60Hz (CN Plug) (R1270)
Included in delivery
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male)
Very bright display makes it easy to read even from a distance.
Switch on. And off you go.
Intelligent operating concept. Ready for operation with just a few quick and easy steps.
Timer. Integrated.
CORIO circulators include an integrated timer function. When the set time has elapsed, a signal sounds and the device switches off. Setting range: 0 ... 999 minutes.
Everything at the front.
All operating controls and safety functions are accessed easily and comfortably from the front.