Refrigerated / heating circulators
for working temperatures from -50 °C to +200 °C
Refrigerated circulators from JULABO temperature control their applications efficiently and hassle-free. High heating/cooling capacities guarantee short heat-up and cool-down times. The refrigerated circulators are available in various sizes and performance classes for flexible use in individual temperature applications. You can use the units for external or internal temperature applications at any time.
The design of every refrigerated circulator is made for easy and time-saving operation. The detachable venting grid allows unavoidable dust to be removed quickly. With the practical drain tap on the front of the units, you can cleanly drain the bath fluid directly on site. Model-dependent handles or castors make transport easier and enable a change of location at any time. A typical application of our refrigerated circulators is the temperature control of external, closed consumers, such as photometers, refractometers, viscometers, etc. In parallel, smaller objects can be temperature-controlled directly in the circulator bath.
Product Features
- Working temperature from -50 °C to +200 °C
- State-of-the-art control technology for quick and highly precise results
- All products feature user-friendly, intuitive operation
- Extra bright displays, easy to read from a distance
Product Overview
CORIO CD refrigerated / heating circulators
The new generation of laboratory circulators for routine work and standard tasks
Refrigerated / heating circulators of the CORIO CD series distinguish themselves with a great price-to-performance ratio. Durable and dependable, they are suitable for a wide range of standard and routine work in both laboratories and industrial environments.
Model | Add to compare CORIO CD-200F |
Add to compare CORIO CD-201F |
Add to compare CORIO CD-300F |
Add to compare CORIO CD-310F |
---|---|---|---|---|
Working temperature range (°C) | -20 ... +150 | -20 ... +150 | -25 ... +150 | -30 ... +150 |
Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
Cooling capacity (kW) | 0.22 | 0.22 | 0.31 | 0.31 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 15 | 15 | 15 | 15 |
Circulation capacity pressure (bar) | 0.35 | 0.35 | 0.35 | 0.35 |
Model | Add to compare CORIO CD-449F |
Add to compare CORIO CD-450F |
Add to compare CORIO CD-600F |
Add to compare CORIO CD-601F |
---|---|---|---|---|
Working temperature range (°C) | -32 ... +150 | -30 ... +150 | -35 ... +150 | -35 ... +150 |
Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
Cooling capacity (kW) | 0.45 | 0.45 | 0.6 | 0.6 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 15 | 15 | 15 | 15 |
Circulation capacity pressure (bar) | 0.35 | 0.35 | 0.35 | 0.35 |
Model | Add to compare CORIO CD-800F |
Add to compare CORIO CD-1000F |
Add to compare CORIO CD-1000FW |
Add to compare CORIO CD-1001F |
---|---|---|---|---|
Working temperature range (°C) | -40 ... +150 | -40 ... +150 | -40 ... +150 | -38 ... +100 |
Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
Cooling capacity (kW) | 0.85 | 1 | 1 | 1 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 15 | 15 | 15 | 15 |
Circulation capacity pressure (bar) | 0.35 | 0.35 | 0.35 | 0.35 |
Model | Add to compare CORIO CD-1200F |
Add to compare CORIO CD-1200FW |
---|---|---|
Working temperature range (°C) | -40 ... +150 | -40 ... +150 |
Temperature stability (°C) | ±0.03 | ±0.03 |
Cooling capacity (kW) | 1.25 | 1.25 |
Heating capacity (kW) | 2 | 2 |
Pump capacity flow pressure (l/min) | 15 | 15 |
Circulation capacity pressure (bar) | 0.35 | 0.35 |
CORIO CP refrigerated / heating circulators
with an enhanced pump performance and a temperature range up to +200 °C
Refrigerated circulators from the CORIO CP range are suitable for applications with a temperature range up to +200°C. The enhanced pump performance ensures they are suitable for easy temperature control tasks in combination with external applications.
Model | Add to compare CORIO CP-200F |
Add to compare CORIO CP-201F |
Add to compare CORIO CP-300F |
Add to compare CORIO CP-310F |
---|---|---|---|---|
Working temperature range (°C) | -20 ... +200 | -20 ... +200 | -25 ... +200 | -30 ... +200 |
Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
Cooling capacity (kW) | 0.2 | 0.2 | 0.3 | 0.3 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
Circulation capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
Model | Add to compare CORIO CP-450F |
Add to compare CORIO CP-449F |
Add to compare CORIO CP-600F |
Add to compare CORIO CP-601F |
---|---|---|---|---|
Working temperature range (°C) | -30 ... +200 | -32 ... +200 | -35 ... +200 | -35 ... +200 |
Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
Cooling capacity (kW) | 0.44 | 0.44 | 0.6 | 0.6 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
Circulation capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
Model | Add to compare CORIO CP-800F |
Add to compare CORIO CP-1000F |
Add to compare CORIO CP-1000FW |
Add to compare CORIO CP-1001F |
---|---|---|---|---|
Working temperature range (°C) | -40 ... +200 | -50 ... +200 | -50 ... +200 | -38 ... +100 |
Temperature stability (°C) | ±0.03 | ±0.03 | ±0.03 | ±0.03 |
Cooling capacity (kW) | 0.84 | 1 | 1 | 1 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
Circulation capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
Model | Add to compare CORIO CP-1200F |
Add to compare CORIO CP-1200FW |
---|---|---|
Working temperature range (°C) | -50 ... +200 | -50 ... +200 |
Temperature stability (°C) | ±0.03 | ±0.03 |
Cooling capacity (kW) | 1.24 | 1.24 |
Heating capacity (kW) | 2 | 2 |
Pump capacity flow pressure (l/min) | 8 ... 27 | 8 ... 27 |
Circulation capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 |
MAGIO MX refrigerated / heating circulators
Our most powerful laboratory circulators with the highest cooling and heating capacity
As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. These devices provide extra powerful pressure and suction pumps and have an incredibly high heating output of 3 kW, enabling even more dynamic temperature control for external applications.
Model | Add to compare MAGIO MX-1800F |
Add to compare MAGIO MX-2500F |
---|---|---|
Working temperature range (°C) | -50 ... +200 | -50 ... +200 |
Temperature stability (°C) | ±0.01 | ±0.01 |
Cooling capacity (kW) | 1.87 | 2.57 |
Heating capacity (kW) | 3 | 3 |
Pump capacity flow pressure (l/min) | 16 ... 31 | 16 ... 31 |
Circulation capacity pressure (bar) | 0.24 ... 0.92 | 0.24 ... 0.92 |
DYNEO DD refrigerated / heating circulators
New temperature control technology for demanding applications
Refrigerated circulators of the DYNEO series distinguish themselves with a great price-performance ratio. The instruments offer high heating/cooling capacities for short heat-up and cool-down times. The refrigerated circulators work precisely and reliably even at higher ambient temperatures up to +40 °C. Either in basic research, in material testing or in technical systems – the DYNEO refrigerated circulators offer functional solutions for every requirement and budget.
Model | Add to compare DYNEO DD-200F |
Add to compare DYNEO DD-201F |
Add to compare DYNEO DD-300F |
Add to compare DYNEO DD-310F |
---|---|---|---|---|
Working temperature range (°C) | -20 ... +200 | -20 ... +200 | -25 ... +200 | -30 ... +200 |
Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
Cooling capacity (kW) | 0.2 | 0.2 | 0.3 | 0.3 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
Circulation capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
Model | Add to compare DYNEO DD-449F |
Add to compare DYNEO DD-450F |
Add to compare DYNEO DD-600F |
Add to compare DYNEO DD-601F |
---|---|---|---|---|
Working temperature range (°C) | -32 ... +200 | -30 ... +200 | -35 ... +200 | -35 ... +200 |
Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
Cooling capacity (kW) | 0.44 | 0.44 | 0.6 | 0.6 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
Circulation capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
Model | Add to compare DYNEO DD-800F |
Add to compare DYNEO DD-1000F |
Add to compare DYNEO DD-1000FW |
Add to compare DYNEO DD-1001F |
---|---|---|---|---|
Working temperature range (°C) | -40 ... +200 | -50 ... +200 | -50 ... +200 | -38 ... +100 |
Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
Cooling capacity (kW) | 0.84 | 1 | 1 | 1 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 8 ... 27 | 8 ... 27 | 8 ... 27 | 8 ... 27 |
Circulation capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 | 0.1 ... 0.7 |
Model | Add to compare DYNEO DD-1200F |
Add to compare DYNEO DD-1200FW |
---|---|---|
Working temperature range (°C) | -50 ... +200 | -50 ... +200 |
Temperature stability (°C) | ±0.01 | ±0.01 |
Cooling capacity (kW) | 1.24 | 1.24 |
Heating capacity (kW) | 2 | 2 |
Pump capacity flow pressure (l/min) | 8 ... 27 | 8 ... 27 |
Circulation capacity pressure (bar) | 0.1 ... 0.7 | 0.1 ... 0.7 |
MAGIO MS refrigerated / heating circulators
with extremely powerful pressure/suction pump and intuitive touch display
As with all circulators from the MAGIO range, the refrigerated circulators stand out thanks to their premium quality, high performance and intuitive operation. The devices offer extra strong pressure and suction pumps, thus fulfilling the highest demands for temperature control of external applications. Whether in basic research, material testing or technical systems – the MAGIO refrigerated circulators offer high-tech solutions for high customer requirements.
Model | Add to compare MAGIO MS-310F |
Add to compare MAGIO MS-449F |
Add to compare MAGIO MS-450F |
Add to compare MAGIO MS-600F |
---|---|---|---|---|
Working temperature range (°C) | -30 ... +200 | -30 ... +200 | -30 ... +200 | -35 ... +200 |
Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
Cooling capacity (kW) | 0.33 | 0.46 | 0.46 | 0.6 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 16 ... 31 | 16 ... 31 | 16 ... 31 | 16 ... 31 |
Circulation capacity pressure (bar) | 0.24 ... 0.92 | 0.24 ... 0.92 | 0.24 ... 0.92 | 0.24 ... 0.92 |
Model | Add to compare MAGIO MS-601F |
Add to compare MAGIO MS-800F |
Add to compare MAGIO MS-1000F |
Add to compare MAGIO MS-1000FW |
---|---|---|---|---|
Working temperature range (°C) | -35 ... +200 | -40 ... +200 | -50 ... +200 | -50 ... +200 |
Temperature stability (°C) | ±0.01 | ±0.01 | ±0.01 | ±0.01 |
Cooling capacity (kW) | 0.6 | 0.86 | 1 | 1 |
Heating capacity (kW) | 2 | 2 | 2 | 2 |
Pump capacity flow pressure (l/min) | 16 ... 31 | 16 ... 31 | 16 ... 31 | 16 ... 31 |
Circulation capacity pressure (bar) | 0.24 ... 0.92 | 0.24 ... 0.92 | 0.24 ... 0.92 | 0.24 ... 0.92 |
Model | Add to compare MAGIO MS-1200F |
Add to compare MAGIO MS-1200FW |
---|---|---|
Working temperature range (°C) | -50 ... +200 | -50 ... +200 |
Temperature stability (°C) | ±0.01 | ±0.01 |
Cooling capacity (kW) | 1.26 | 1.26 |
Heating capacity (kW) | 2 | 2 |
Pump capacity flow pressure (l/min) | 16 ... 31 | 16 ... 31 |
Circulation capacity pressure (bar) | 0.24 ... 0.92 | 0.24 ... 0.92 |