FL601 Recirculating Coolers for installation below a lab bench
compact models with up to 1.7 kW of cooling capacity for installation below a lab bench
The compact FL models are suited for a wide variety of cooling tasks. Installation under a lab bench saves valuable space. 2 variants: Air-cooled (FL) and water-cooled (FLW).
Order number including voltage version | 9661006.03 |
---|---|
Working temperature range | -20 ... +40 °C |
Temperature stability | ±0.5 °C |
Pump capacity flow pressure | 23 l/min |
Pump capacity pressure | 1 bar |
Filling volume | 5.5 ... 8 l |
Total dimensions
(W × L × H) |
32 x 50 x 62 cm |
Product Features
- Ergonomic design and easy operation
- Splash-proof keypad
- Large, bright LED display
- Reliable Microprocessor PID temperature control
- Powerful immersion pumps, suitable for continuous operation
- Permissible temperature in return line +80°C
- Easy filling and Drain tap easily accessible
- Low liquid level protection with optical and audible alarm signal
- Integrated stainless steel bath tanks
- Front drain
- No side vents, instruments can be placed right next to other equipment
- RS232 interface for PC connection
- IP class according to IEC 60529: 21
- Alarm output, potential-free change-over contact (max. 30 VA)
Technical data for FL601
Total dimensions (W × L × H) |
32 x 50 x 62 cm |
---|---|
Filling volume | 5.5 ... 8 l |
Weight | 48 kg |
Pump connections | M16x1 male |
Barbed fittings inner diameter | 8/12 mm |
Working temperature range | -20 ... +40 °C |
---|---|
Temperature stability | ±0.5 °C |
Setting the resolution of the temperature display | 0.1 °C |
Temperature display resolution | 0.1 °C |
Ambient temperature | +5 ... +40 °C |
Return flow temperature max. | 80 °C |
Cooling capacity
1 Performance specifications measured in accordance with DIN 12876. Cooling capacities up to 20 °C measured with ethanol; over 20 °C with thermal oil unless otherwise specified. Performance specifications apply at an ambient temperature of 20 °C. Performance values may differ with other bath fluids. |
||||||||||||||||||||||
Pump capacity flow pressure | 23 l/min | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pump capacity pressure | 1 bar | |||||||||||||||||||||
Power consumption | 5 A |
Bath tank | Stainless steel |
---|
Cooling of compressor | 1-stage Air |
---|
Sound pressure level | 55 dbA |
---|---|
Classification according to DIN12876-1 |
Classification I (NFL) |
IP Code according to IEC 60529 |
IP 21 |
Pump type | Centrifugal Pump |
Interfaces | RS232 |
---|---|
Temperature control | PID1 |
Temperature display | LED |
Temperature setting | Keypad |
9661006.13 | 230V/60Hz (Nema N6-20 Plug) (R449A) |
---|---|
9661006.02 | 115V/60Hz (Nema N5-15 Plug) (R449A) |
9661006.03 | 230V/50Hz (Schuko Plug - CEE 7/4 Plug Type F) (R452A) |
9661006.04 | 230V/50Hz (UK Plug Type BS1363A) (R452A) |
9661006.05 | 230V/50Hz (CH Plug Type SEV 1011) (R452A) |
2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) |
Accessory for FL601
Downloads for FL601
We would also be happy to send you our printed catalogs and brochures by post.
Request brochureFL601 Benefits
100% Checked.
100% testing. 100% quality. Each JULABO Circulator undergoes thorough quality testing before leaving the factory.
Green technology.
Development consistently applied environmentally friendly materials and technologies.
JULABO. Quality.
Highest standards of quality for a long product life.
Quick start.
Individual JULABO consultation and comprehensive manuals at your disposal.
Related Products
Products with similar properties